Specifications

Imaging performance
Thermal
Field of view (FOV)*
Spatial resolution (IFOV)*
Min focus distance*
Thermal sensitivity (NETD)
Detector data acquisition /
Image frequency
Focus
IR digital zoom
Detector type
Spectral band
Digital image enhancement
Visual
(IR-Fusion models only)
On camera operating modes
Visible light camera
Visible light digital zoom
Temperature measurement
Calibrated temperature range
Optional - High temperature
Accuracy
Measurement modes
Emissivity correction
Image presentation
Digital display
LCD backlight
Video output
Palettes
Optional lenses
54 mm Telephoto lens
Field of view (FOV)
Spatial resolution (IFOV)
Min focus distance
10.5 mm wide angle lens
Field of view (FOV)
Spatial resolution (IFOV)
Min focus distance
Image and data storage
Storage medium
File formats supported
Interfaces and software
Interface
Software
Laser (IR-Fusion models only)
Classifi cation
Laser targeting
Controls and adjustments
Set-up controls
Image controls
On-screen indicators
Power
Battery type
Battery operating time
Battery charging
AC operation
Power saving
Environmental and mechanical
Operating temperature
design
Storage temperature
Relative humidity
Water and dust resistant
Weight (including batteries)
Camera size (HxWxD)
Warranty
Other
*standard 20 mm Germanium lens
Fluke Ti45
≤0.08 °C at 30 °C
SmartFocus; one fi nger continuous focus
2x
160 x 120 Focal Plane Array, Vanadium Oxide (VOx) Uncooled Microbolometer
Full thermal, full visual light or merged
thermal-visual images.
Picture-in-Picture
2x
-20 °C to 600 °C (-4 ºF to 1112 ºF) in 3 ranges -20 °C to 350 °C (-4 ºF to 662 ºF) in 2 ranges
Range 1 = -20 °C to 100 °C (-4 ºF to 212 ºF)
Range 2 = -20 °C to 350 °C (32 ºF to 662 ºF)
Range 3 = 250 °C to 600 °C (482 ºF to 1112 ºF)
Up to 1200 °C (2192 ºF)
Range 4 = 500 °C to 1200 °C (932 ºF to 2192 ºF)
±2 °C or 2% (whichever is greater)
Centerpoint, center box (area min/max,
average), moveable spots/boxes, user
defi ned fi eld/text annotations, isotherms,
automatic hot and cold point detection,
visible color alarm above and below
5" large high-resolution digital display
RS170 EIA/NTSC or CCIR/PAL composite video
Grayscale, grayscale inverted, blue red, high contrast, hot metal, ironbow, amber, amber inverted
Compact fl ash card stores over 1000 IR images (512MB card standard)
14 bit measurement data included. Exportable JPEG, BMP, PCX, PNG, PSD.
SmartView; Full analysis and reporting software included
Laser dot visible on screen when blending thermal and visible image
Date/time, temperature units C/F, language, scale, LCD intensity (high/normal/low)
Level, span, auto adjust (continuous/manual)
Battery status, target emissivity, background temperature and realtime clock
Li-Ion smart battery, rechargeable, fi eld-replaceable
3 hours continuous operation (2 hours for models with IR-Fusion)
2 bay intelligent charger powered via AC outlet
AC adapter 110/220 VAC, 50/60 Hz
Automatic shutdown and sleep modes (user specifi ed)
Operating and storage 10% to 95%, non-condensing
162 x 262 x 101mm (6.5" x 10.5" x 4.0")

Included accessories

Heavy duty carrying case
2 rechargeable battery packs
Battery charger
AC adapter (for Ti45 only)
Video cable
512 MB compact flash card
Compact flash card reader and
USB cable
PCMCIA compact flash card reader
Neck strap
SmartView reporting and analysis
software on CD
User manual on CD
Visit the Fluke web site for complete specifi cations
Fluke Ti40
23° horizontal x 17° vertical
2.60 mrad
0.15 m
≤0.09 °C at 30 °C
30 Hz/30 Hz
-
8 µm to 14 µm
Automatic full-time enhanced
Full thermal or full visual light.
Merge thermal-visual images in SmartView
software. Picture-in-Picture
1280 x 1024 pixels, full color
-
Range 1 = -20 °C to 100 °C (-4 ºF to 212 ºF)
Range 2 = -20 °C to 350 °C (32 ºF to 662 ºF)
-
-
-
Centerpoint, center box
(area min/max, average)
0.1 to 1.0 (0.01 increments)
Sunlight readable color LCD
High precision Germanium lens
9° horizontal x 6° vertical
0.94 mrad
0.6 m
High precision Germanium lens
42° horizontal x 32° vertical
4.9 mrad
0.3 m
Compact fl ash card reader included
Class II
-
-10 °C to +50 °C (14 °F to 122 °F)
-40 °C to +70 °C (-40 °F to 158 °F)
IP54
1.95 kg (4.3 lbs)
2 years

Ordering information*

FLK Ti40-20
IR FlexCam Thermal
Imager
FLK Ti40FT-20
IR FlexCam Thermal
Imager with Fusion
FLK Ti45-20
IR FlexCam Thermal
Imager
FLK Ti45FT-20
IR FlexCam Thermal
Imager with Fusion
*For ordering information of optional
lenses check the Fluke web
To fi nd out more about
Fluke thermal imagers go to
www.fl uke.com/thermography
or in the United States call
1-800-760-4523.
Fluke. Keeping your world

up and running.

Fluke Corporation
PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2006 Fluke Corporation. All rights reserved.
Printed in U.S.A. 5/2006 2674273 D-US-N Rev A

Advertisement

loading

This manual is also suitable for:

Ti45ft-20Flexcam ti40ftFlexcam ti45ftFlexcam ti40Flexcam ti45