Connector Pin Assignments; Cable Requirements; Power Cable - American Dynamics SpeedDome Ultra Outdoor Housing ADSDUHOC Installation Manual

Ultra outdoor housing
Table of Contents

Advertisement

Connector Pin Assignments

GREEN CONNECTOR (POWER)
Pin
Color
Description
1
Black
24Vac
2
Red
Common
3
White
24Vac
BLACK CONNECTOR (DATA)
Manchester
Pin
Color*
Designation
1-4
Not used.
5
White/Orange
Manchester (White)
6
White/Yellow
Manchester (Black)
RS-422 / SensorNet
Pin
Color*
Designation
1
Orange
RS-422 Data In High (+)
2
Green
RS-422 Data In Low (–)
3
Yellow
RS-422 Data Out High (+)
4
Brown
RS-422 Data Out Low (–)
5
White/Orange
SensorNet (unshielded)
6
White/Yellow
SensorNet (unshielded)
*Color based on composite cable.
GREEN CONNECTOR (TWISTED PAIR VIDEO)
Pin
Color
Designation
1
+ (video high)
2
– (video ground)
GRAY CONNECTOR (RELAY ALARM OUTPUTS)
Pin
Color
Description
1
Blue
Normally Closed*
2
Purple
Common*
3
Gray
Normally Open*
4
Wht/Red
Alarm Return
5
Wht/Blk
Alarm input 1 (3.5mA sink)
*Relay contact not to exceed 1A @ 30Vdc or
0.3A @ 125Vac.
BLUE CONNECTOR (ALARM INPUT)*
Pin
Color
Designation
1
Wht/Blue
Alarm input 2
2
Wht/Brn
Alarm input 3
3
Wht/Purple
Alarm input 4
4
Wht/Red
Alarm Return
* 0101-0115-0X non-vandal resistant housing,
0101-0116-0X vandal-resistant housing.
SPEEDDOME ULTRA OUTDOOR HOUSING
INSTALLATION GUIDE - CONTINUATION

Cable Requirements

Data Cable
The table below shows requirements for SensorNet,
RS-422, and Manchester networks. For more
information about communication protocols and
cable networks, see Communication Protocols and
Cable Networks, 8000-2573-19.
Data cable requirements
SensorNet
Cable type
1
unshielded,
twisted
pair*
Wire gauge
22 AWG
Connection
Non-
polarized
Max.
32
devices on
line
*
Power, data, and video cables can be ordered
separately or within a composite cable that can be
ordered in various lengths. Plenum-rated cables must
be used in indoor ceilings used for environmental air
return (called "other air space" in the National Electrical
Code). Order parts through your distribution network.
Note: If you order cable from an outside source, wire
colors may be different.
** Belden 88760 (plenum), or Belden 8760 cable (non-
plenum) cable is recommended. Plenum-rated cables
must be used in indoor ceilings used for environmental
air return (called "other air space" in the National
Electrical Code). Order cable directly from Belden by
calling 1-800-235-3361.

Power Cable

The camera dome and housing are to be connected
to a Class 2 LPS, 24Vac, 80VA power source. Do
not exceed the maximum outdoor Class 2 ratings of
30Vac, 100VA.
Low Line Voltage
102/204Vac
Low Line Voltage
90/180Vac
6 of 12
RS-422
Manchester
2
1
shielded,
shielded
twisted
twisted
pair*
pair**
22 AWG
18 AWG
Polarized
Polarized
10
3
2
2
0.823mm
1.31mm
2.08mm
(18AWG)
(16AWG)
(14AW)G
60m
100m
(200ft)
(320ft)
30m
50m
(100ft)
(160ft)
8200-0492-02, REV. C
2
160m
(520ft)
80m
(260ft)

Advertisement

Table of Contents
loading

Table of Contents