TYPICAL GAS SUPPLY
INSTALLATION (CONT.)
Gas line piping (continued)
■ Copper tubing must be tin-lined if the gas contains
more than 0.3 grams of hydrogen sulfide per 100 cubic
feet of gas.
■ Plastic tubing is suitable only for outdoor,
underground use.
■ Gas piping in contact with earth, or any other material
which may corrode the piping, must be protected
against corrosion in an approved manner.
■ Underground piping must have a minimum of 18" cover.

Test connections

All connections and joints must be thoroughly tested for
leaks in accordance with local codes and all listed
procedures in the latest edition of ANSI Z223.1/NFPA 54.
DANGER
Do not use an open flame to check for gas
leaks. Be sure there are no sparks or open
flames in the area while you check for gas
leaks. This will result in a fire or explosion
which can cause serious bodily injury or death,
and damage to property.
Regulator
The regulator should be adequately supported.
■ The regulator must be installed close to
the appliance.
■ Each appliance must have a separate regulator.
CONNECT GAS SUPPLY
TO REGULATOR
Hard pipe the gas supply to the inlet of the regulator.
Make a "T" fitting from your hard pipping if you plan on
adding additional Vieluxe
Refer to "Typical Gas Supply Installation".
Connect the corrugated gas line to the regulator. Figure 1.
Figure 2 shows the gas line and regulator assembled.
Hard pipe the gas supply to the regulator. Figure 3.
Figure 1
Gas supply to manifold
Figure 2
Gas supply to manifold
Figure 3
Regulator
Note: Leave an access in the "island" structure for
gas supply and regulator service not inside the grill
structure. Vieluxe
®
has a gas line and regulator
access door available from your dealer or call Vieluxe
Customer Service at 1-866-VIELUXE.
(Vieluxe
®
part number 36311).
5
®
gas appliances.
Regulator
Regulator
Gas supply to
manifold
Hard piped
gas supply

Advertisement