Brocade Communications Systems Brocade 8/12c Documentation Update page 158

Brocade network advisor documentation updates v11.1.x (53-1002363-03, august 2011)
Hide thumbs Also See for Brocade 8/12c:
Table of Contents

Advertisement

E
Database tables and fields
TABLE 297
Field
RX_UTILIZATION
LINK_FAILURE
TX_LINK_RESETS
RX_LINK_RESETS
SYNC_LOSSES
SIGNAL_LOSSES
SEQUENCE_ERRORS
INVALID_TRANSMISSIONS
CRC_ERRORS
LAST_UPDATE_TIME
TABLE 298
Field
PORT_ID
SWITCH_ID
TX
150
SWITCH_PORT_PERFORMANCE
Definition
'The computed value of RX based on speed of port
Count of link failures. This count is part of the Link
Error Status Block (LESB). (FC-PH 29.8). Note, this is
a Fibre Channel only stat
Count of Link resets. This is the number of LRs
received. Note, this is a Fibre Channel only stat
Count of Link resets. This is the number LRs
transmitted. Note, this is a Fibre Channel only stat
Count of instances of synchronization loss detected
at port. This count is part of the Link Error Status
Block (LESB). (FC-PH 29.8). Note, this is a Fibre
Channel only stat.
Count of instances of signal loss detected at port.
This count is part of the Link Error Status Block
(LESB). (FC-PH 29.8). Note, this is a Fibre Channel
only stat
Count of primitive sequence protocol errors detected
at this port. This count is part of the Link Error Status
Block (LESB). (FC-PH 29.8). Note, this is a Fibre
Channel only stat
Count of invalid transmission words received at this
port. This count is part of the Link Error Status Block
(LESB). FC-PH 29.8). Note, this is a Fibre Channel
only stat
Count of frames received with invalid CRC. This count
is part of the Link Error Status Block (LESB). (FC-PH
29.8). Loop ports should not count CRC errors
passing through when monitoring. Note, this is a
Fibre Channel only stat.'
Time when this stats record was updated
SWITCH_TE_PORT_PERFORMANCE
Definition
Primary key of the Switch Port
Primary key of Virtual Switch which this port is
present
The number of octets or bytes that have been
transmitted by this port. One second periodic polling
of the port. This value is saved and compared with
the next polled value to compute net throughput.
Note, for Fibre Channel, ordered sets are not
included in the count.
(Continued)
Brocade Network Advisor Documentation Updates
Format
Size
double
precision
double
precision
double
precision
double
precision
double
precision
double
precision
double
precision
double
precision
double
precision
timestamp
Format
Size
int
int
double
precision
53-1002363-02

Advertisement

Table of Contents
loading

This manual is also suitable for:

Network advisor 11.1.0Brocade bladesystem 4/24

Table of Contents