Configuration procedure
This example only describes multicast ARP configuration on the switch, and is only applicable to multicast
NLB. For NLB configuration on the servers, see the related documents of the Windows Server.
# Specify an IP address for VLAN-interface 2.
<Switch> system-view
[Switch] vlan 2
[Switch-vlan2] port GigabitEthernet 1/0/4
[Switch-vlan2] port GigabitEthernet 1/0/1
[Switch-vlan2] quit
[Switch] interface vlan-interface 2
[Switch-Vlan-interface2] ip address 17.1.1.1 255.255.255.0
[Switch-Vlan-interface2] quit
# Specify an IP address for VLAN-interface 1.
[Switch] interface vlan-interface 1
[Switch-Vlan-interface1] ip address 16.1.1.30 255.255.255.0
[Switch-Vlan-interface1] quit
# Disable the ARP entry check function.
[Switch] undo arp check enable
# Configure a static multicast MAC address entry.
[Switch] mac-address multicast 03bf-1001-0164 interface GigabitEthernet 1/0/2 Gigabi
tEthernet 1/0/3 vlan 1
Verifying the configuration
•
NLB load sharing—Enables the FTP server function of Server A and Server B. Host A and Host B
send requests to the virtual IP address and each of them logs in to a different server.
NLB redundancy—Disables the network interface card of Server A. Host A and Host B send
•
requests to the virtual IP address and both log in to the FTP server on Server B.
9