HOW TO USE FUNCTIONS

Timer setting
First, set the current time on the remote controller.
Procedure to set the current time and day of the week
(If day/time is not set, the indication of time and day of
the week blinks.)
(1) Press the TIME
more to enable the time setting mode.
• The SETTING
(2) Set the current day of the week with the DAY
button.
• Each time the button is pressed, the
shifts cyclically pointing MO → TU → ... → SU →
MO.
(3) Set the current time with the TIME
buttons.
• If you press the buttons long, the current time can
be set in units of 10 minutes.
(4) Press the SET
Heating or cooling operation
Performing heating or cooling operation
• Press the ZONE1, 2
or cooling operation.
The set temperature appears under
the remote controller. (When ZONE2 is provided, the
set temperature appears simultaneously under
.)
• During the heat pump operation or while the internal
heater or backup heater is energized,
displayed.
• Use the OPERATE MODE
cooling operation or heating operation.
Each time this button is pressed, heating
cooling are switched alternately.
• To stop heating or cooling, press the ZONE1, 2
button. The set temperature and
out and the heating or cooling operation stops.
7-EN
or
button for 4 seconds or
segment blinks.
segment
and
button to determine the setting.
button to start heating
button to select
and
Setting temperature
• Press the SELECT
and select
• Change the set temperature with the TEMP.
• The ZONE2 setting temperature must be equal to or
lower than the ZONE1 setting temperature.
Performing Auto mode operation
• The setting temperature can be set automatically
according to the outside temperature.
• Press the AUTO TEMP.
• The temperature indication changes to "A" and the
water temperature is automatically set according to
the outside temperature.
on
To correct the set value for the Auto mode
is
• Press the AUTO TEMP.
seconds or more to enter the auto curve adjusting
mode.
• The function code setting screen appears. Press the
TIME
between -5 to +5°C.
In this case, temperature is displayed as -5, -4, -3,
go
-2, -1, 0, 1, 2, 3, 4, or 5.
Only ZONE1 temperature is displayed.
When the SET
temperature is changed, the set temperature is
registered.
– 8 –
Owner's Manual
button to move
or
button.
button.
button for 4
button to display a temperature
button is pressed after the
.