PACKAGING LIST

Quantity
Description
1
Firebox, burner assembly and outer case (wrap)
1
Installation and Operation Manual
1
Warranty Certificate
1
Screw and wall plug pack
1
Rubber grommet
Surround Assembly
(required - sold separately. see Page 21 for ordering information)
1
Surround Assembly
1
Installation Instruction Sheet

APPLIANCE SPECIFICATIONS

X-Fires™ Wide Screen
Gas Type
Gas inlet pressure
Max.
Min.
Regulator Pressure Setting
Max Energy Input
11,950 BTU/hour
Min Energy Input
Pilot Energy Input
Main burner flow restrictor
1.55 mm (0.063")
(burner orifice)
Oxypilot
Gas Inlet Connection
3/8" NPT at regulator
Ignition
Double Piezo spark
Spark Gap
Please see Data Plate affixed to appliance for current data. This appliance is for use
only with the gas type, and at the pressure stated on the appliance Data Plate.
Table 1

UNPACKING THE APPLIANCE

Remove the straps and the top lid of the outer packaging, remove any
instructions or fixing kits . Read ALL these instructions before continuing
to unpack or install this appliance .
Lift off the remaining packaging components .
Check that the components supplied with the packaging list on Page 7 .
Please dispose of all the packaging materials at your local recycling center .
Fireplace
Natural Gas
Propane Gas
10.5" w.c.
13" w.c.
6" w.c.
11" w.c.
5" w.c.
10" w.c.
10,235 BTU/hour
6,820 BTU/hour
6,820 BTU/hour
560 BTU/hour
560 BTU/hour
1.03mm (0.042")
SIT/Bray 9082
SIT/Bray 9284
3/8" NPT at regulator
Double Piezo spark
1/8" - 3/16"
1/8" - 3/16"

BURN-IN PERIOD

On initial light up of a new appliance, the 'newness' will burn off within
the first few hours of operation . During this period some smoke may be
emitted from outlet grill, this should be no cause for concern . Accord-
ingly, the room should be well ventilated with all windows and doors
open during this period .
Depending on your use, the burn-in period may take a few hours or a few
days . Also if you have a sensitive sense of smell you may notice slight
odors during operating after the burn-in period is over .
KEEP YOUR HOUSE WELL VENTILATED DURING THE BURN-IN PERIOD.
THE ODOR AND HAZE EMITTED DURING THE BURN-IN PERIOD CAN BE
QUITE NOTICEABLE AND MAY SET OFF A SMOKE DETECTOR. MAKE
SURE SMOKE DETECTORS ARE NOT TOO CLOSE TO THE FIREBOX
(CHECK WITH YOUR LOCAL CODE FOR ALLOWABLE DISTANCES).
CODES
Adhere to all local codes or in their absence the latest edition of The
National Fuel Gas Code ANSI Z223 .1 / NFPA 54 - latest edition which can
be obtained from The American National Standards Institute, Inc . (1430
Broadway, New York, NY, 10018) or National Fire Protection Association,
Inc . (Batterymarch Park, Quincy, MA, 02269) .
Seller of unvented propane or natural gas fired supplemental room
heaters in the Commonwealth of Massachusetts shall provide to each
purchaser a copy of 527 CMR 30 upon sale of the unit .
This Lennox Hearth Products Unvented Gas Room Heater is certified by
OMNI-Test Laboratories, Inc to ANSI Z21 .11 .2 standard .
Massachusetts Requirements
These fireplaces are approved for installation in the US state of Mas-
sachusetts if the following additional requirements are met:
• Unvented Room Heaters shall be installed in accordance with 527
CMR and 248 CMR:
• Installation and repair must be done by a plumber or gas fitter licensed
in the Commonwealth of Massachusetts
• The flexible gas line connector used shall not exceed 36 inches (92
centimeters) in length .
• The individual manual shut-off must be a T-handle type valve .
• Vent-Free appliances may NOT be installed in bedrooms or bathrooms .
• A working smoke detector must be installed in the area where vent-
free appliances are installed .
Seller of unvented propane or natural gas-fired supplemental room heaters
shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit .
New York:
These fireplaces are approved for installation in the US state of New York,
but not in New York City .
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

X-fires-ws-lp

Table of Contents