Installation Of The Boiler; Wall Mounting Bracket; Mounting The Boiler; Assembly Practice - Keston K130 Installation And Servicing Instructions

Fan powered high efficiency condensing gas boiler
Table of Contents

Advertisement

WD52/0/1997
Read Chapter 2 - Boiler Location and decide upon the position of the boiler.
Installation of the boiler is straightforward but consideration must be given to access to allow flue
and air pipes to be pushed through walls and ceilings. The order in which the components are
installed will depend upon particular site conditions, but in general it will be easiest and most
accurate to install the boiler and then build up the flue outlet and air inlet pipes to the terminal - this
is the sequence described.
3.1

WALL MOUNTING BRACKET

a
Place the bracket on the wall
horizontally with the pre-drilled
holes at the bottom.
b
Drill through the centre hole of
the bracket, plug the hole and fix
in position.
c
Using a spirit level make sure
the bracket is completely level
and mark the position of the
other screw holes.
d
Remove the bracket and drill the
holes in the positions marked.
Plug these holes.
e
Screw the bracket to the wall
using screws of an appropriate
size for the wall type (No. 12 x 2
inch wood screws normally
suffice).
f
Mark the bottom fixing hole and
drill for a No 8 x 1 inch wood
screw. Insert plug.
3.2

MOUNTING THE BOILER

a
Lift and locate the upper rear lip on the boiler to the boiler wall bracket.
b
Move the boiler sideways to centralise the boiler on the bracket.
c
Screw in the lower fixing screw.
3.3

ASSEMBLY PRACTICE

Remove all plastic debris and burrs when installing air intake piping. Plastic filings caused
by cutting muPVC pipe must not be allowed to be drawn into the filter or combustion air
blower. Prevent dust entering the air intake when cutting on building sites. Blower failure
which is determined to be caused by plastic filings or other debris will not be covered by
guarantee.
Combustion air filters are fitted to the Keston condensing boilers as standard. This
filter must be examined at least once every year, and more often in particularly
dusty and dirty areas.
Installation & Servicing Instructions
Chapter 3 : Installation

3. INSTALLATION OF THE BOILER

The Keston 130 Condensing Boiler
93
280
Figure 3.1 Wall Mounting Fixing Locations
All dimensions in mm.
250
Page : 16