Regulatory Compliance As of the date of manufacture, the CHV-RTS and CHV-RTHS have been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling. Federal Communications Commission (FCC) Compliance Statement CAUTION: Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user’s authority to operate the equipment.
500 feet (152 meters) from the thermostat. One-piece mounting and a single non-polarized twisted-pair connection make the CHV-RTS and CHV-RTHS simple to install. The 1 1/2 inch (39 mm) diameter face of each protrudes just 1/8 inch (3 mm) from the wall surface and is easily painted or wallpapered to blend into the wall surface.
Temperature & Humidity Sensors Crestron CHV-RTS & CHV-RTHS Specifications Specifications for the CHV-RTS and CHV-RTHS are listed in the following table. CHV-RTS and CHV-RTHS Specifications SPECIFICATION DETAILS Measurement Range Indoor Temperature 0° to 110° F (-18° to 43° C) Outdoor Temperature -30º...
Physical Description This section provides information on the connections, controls, and indicators available on the CHV-RTS and CHV-RTHS. CHV-RTS and CHV-RTHS Physical View CHV-RTS and CHV-RTHS Overall Dimensions (Top and Side Views) 2.22 in (57 mm) Ø1.50 in (39 mm)
Sensors are suitable for mounting in dry or damp locations as defined by the National Electrical Code. Complete the following procedure to install the CHV-RTS or CHV-RTHS. 1. Locate an area on the wall that is free of miscellaneous wiring and studs.
However, keep the small gap around the outer edge clear of any obstructions. Hardware Hookup CHV-RTS and CHV-RTHS sensors connect to the terminal blocks on the back plate of the CHV-TSTAT, CHV-THSTAT, CHV-TSTATEX, and CHV-TSTATEX-FCU thermostats (all sold separately).
Page 10
Temperature & Humidity Sensors Crestron CHV-RTS & CHV-RTHS NOTE: Sensor wiring is non-polarized. NOTE: Up to two CHV-RTS sensors or one CHV-RTHS sensor may be connected to a single channel. NOTE: Use a separate run of wire for each sensor.
Page 11
NETWORK 4. To connect sensors using two channels on the thermostat, wire up to two CHV-RTS sensors to the RS1 and RSR terminals and up to two additional CHV-RTS sensors (or one CHV-RTHS sensor) to the RS2 and RSR terminals as shown in the illustration on the following page.
Page 12
Temperature & Humidity Sensors Crestron CHV-RTS & CHV-RTHS Dual CHV-RTS and Single CHV-RTHS Hookup (Three Sensors Shown) CHV-RTHS CHV-RTS CHV-RTS NETWORK 5. Note the orientation of the front plate connection pins and reattach the front plate (making sure the front plate snaps in place and no wires are pinched).
Crestron CHV-RTS & CHV-RTHS Temperature & Humidity Sensors Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. CHV-RTS and CHV-RTHS Troubleshooting TROUBLE POSSIBLE CORRECTIVE ACTION...
[1-888-273-7876] or, for assistance within a particular geographic region, refer to the listing of Crestron worldwide offices at www.crestron.com/offices. To post a question about Crestron products, log onto Crestron’s Online Help at www.crestron.com/onlinehelp. First-time users must establish a user account to fully benefit from all available features.
(property or economic damages inclusive) arising from the sale or use of this equipment. Crestron is not liable for any claim made by a third party or made by the purchaser for a third party.
Page 16
Crestron Electronics, Inc. Installation Guide – DOC. 8189D 15 Volvo Drive Rockleigh, NJ 07647 (2002205) Tel: 888.CRESTRON 11.13 Fax: 201.767.7576 Specifications subject to www.crestron.com change without notice.