Crestron CNX-TS Operations & Installation Manual
Crestron CNX-TS Operations & Installation Manual

Crestron CNX-TS Operations & Installation Manual

Single gang temperature sensor

Advertisement

Quick Links

Crestron CNX-TS
Single Gang Temperature Sensor
Operations & Installation Guide

Advertisement

Table of Contents
loading

Summary of Contents for Crestron CNX-TS

  • Page 1 Crestron CNX-TS Single Gang Temperature Sensor Operations & Installation Guide...
  • Page 2 This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. ©2002 Crestron Electronics, Inc.
  • Page 3: Table Of Contents

    Crestron CNX-TS Contents Single Gang Temperature Sensor: CNX-TS Introduction...1 Features and Functions ...1 Specifications...2 Physical Description ...2 Industry Compliance...4 Setup...5 Network Wiring ...5 Identity Code ...6 Installation ...7 Programming...8 Programming with SIMPL Windows...8 Programming with VT Pro-e ...13 Problem Solving...13 Troubleshooting...13...
  • Page 5: Single Gang Temperature Sensor: Cnx-Ts

    CNX-TS Introduction Features and Functions The CNX-TS is a wall-mounted single gang temperature sensor that can be part of a Crestron Home™ total control system. The temperature sensor is a standard Cresnet device, and provides temperature sensing when the control system is properly programmed using SIMPL™...
  • Page 6: Specifications

    The latest software versions can be obtained from the Downloads | Software Updates section of the Crestron website (www.crestron.com). Refer to the NOTE after footnote 4. 2. Crestron 2-Series control systems include the AV2, PAC2, PRO2, RACK2, CP2, and MP2. 3. CNX update files are required for either CNMSX-AV/Pro or CNRACKX/-DP. Filenames for CNX update files have a UPZ extension, and ST-CP files are in one EXE or zipped UPZ file.
  • Page 7 Front View 1.788 in 4.542 cm 4.158 in 10.562 cm 6.884 cm Static sensitive device, observe electrostatic discharge (ESD) precautions. Single Gang Temperature Sensor: CNX-TS • 3 Side Views 1.400 in* 3.556 cm Back View 1.693 in 4.301 cm Speaker 2.710 in...
  • Page 8: Industry Compliance

    (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 4 • Single Gang Temperature Sensor: CNX-TS Single gang electrical box (2.5 in. depth recommended) Sensor unit 1 in.
  • Page 9: Setup

    If the unit is a home-run from a Crestron system power supply network port, the power factor of that unit is the power factor of the entire run. The...
  • Page 10: Identity Code

    The software checks the baud rate and then opens the "Set Network ID" window. In the "Set Network ID" window, select the CNX-TS from the Current Network Devices text window. From the Choose the new network ID for the selected device (Hex): text box, select the new NET ID for the sensor.
  • Page 11: Installation

    Make sure that all excess wire is completely inside the electrical box and not between the box and the sensor. The CNX-TS contains an electrostatic sensitive device (ESD). Observe precautions for handling ESDs to avoid damaging unit.
  • Page 12: Programming

    • SIMPL Windows version 2.01.05, or later. Requires SIMPL+ Cross Compiler version 1.1 (Library update file 183 or later) • VT Pro-e version 2.4 or later • Crestron Database version 15.7.2 or later (version 15.8.2 if you use sounds) Programming with SIMPL Windows NOTE: The following assumes that the reader has knowledge of SIMPL Windows.
  • Page 13 Expanded PRO2 System Tree C2Net-Device Slot in Configuration Manager The C2Net-Device Slot can accept a sensor such as the CNX-TS. Once a sensor is configured in a C2Net-Device Slot, the slot allows Cresnet communication between the sensor and the control system.
  • Page 14 Slot 9, with a default NET ID of 53. C2Net Device, Slot 9 Double-click the CNX-TS icon in the upper pane to open the “Device Settings” window. This window displays CNX-TS device information. The NET ID can be changed in this window using the NET ID tab.
  • Page 15 The following graphic shows the CNX-TS symbol in the SIMPL Windows’ Programming Manager. Detail View of the CNX-TS symbol in SIMPL Windows’ Programming Manager The following two tables list inputs and outputs, respectively, and their functional descriptions.
  • Page 16 *Sound20 is the sound assignment to join20. Sounds must be assigned in VTPro-e and the resulting project loaded. Refer to the VT Pro-e help file for more information. To create additional sound symbols in SIMPL Windows, right click on the CNX-TS symbol and select Insert Symbol/Parameter Field (alternatively, select Alt +).
  • Page 17: Programming With Vt Pro-E

    Crestron CNX-TS Programming with VT Pro-e To play WAV files, a CNX-TS project must be created in VT Pro-e (with the WAV files and correct join numbers as part of the project). NOTE: If you need to create WAV files, refer to Windows Help (Using Sound Recorder).
  • Page 18: Further Inquiries

    If after reviewing this Operations and Installation Guide, you cannot locate specific information or have questions, please take advantage of Crestron's award winning customer service team by calling: • In the US and Canada, call Crestron’s corporate headquarters at 1-888-CRESTRON [1-888-273-7876]. • In Europe, call Crestron International at +32-15-50-99-50.
  • Page 19: Software License Agreement

    This Agreement may only be modified by a writing signed by an authorized officer of Crestron. Updates may be licensed to You by Crestron with additional or different terms. This is the entire agreement between Crestron and You relating to the Software and it supersedes any prior representations, discussions, undertakings, communications or advertising relating to the Software.
  • Page 20 “applets” incorporated into the Software), the accompanying media and printed materials, and any copies of the Software are owned by Crestron or its suppliers. The Software is protected by copyright laws and international treaty provisions. Therefore, you must treat the Software like any other copyrighted material, subject to the provisions of this Agreement.
  • Page 21: Return And Warranty Policies

    CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended, or if it has been subjected to misuse, accidental damage, modification, or improper installation procedures.
  • Page 22 Single Gang Temperature Sensor Crestron CNX-TS This page intentionally left blank. 18 • Single Gang Temperature Sensor: CNX-TS Operations & Installation Guide - DOC. 8191...
  • Page 23 Crestron CNX-TS Single Gang Temperature Sensor This page intentionally left blank. Single Gang Temperature Sensor: CNX-TS • 19 Operations & Installation Guide - DOC. 8191...
  • Page 24 Crestron Electronics, Inc. Operations & Installation Guide - DOC. 8191 15 Volvo Drive Rockleigh, NJ 07647 08.02 Tel: 888.CRESTRON Fax: 201.767.7576 Specifications subject to www.crestron.com change without notice.

Table of Contents