Technical Specifications 9 - Lab.gruppen FP14000 Operation Manual

Dedicated touring amplifiers fp+ series
Hide thumbs Also See for FP14000:
Table of Contents

Advertisement

Following are the FP+ Series technical specifications. These figures are accurate at the time of printing but
please note that all figures are subject to change without notice. For the most accurate and current information
available, please visit www.labgruppen.com.
Model
Number of channels
Peak total output all channels driven
Peak output voltage per channel
Max. output current per channel
Max. Output Power
16 ohms per ch. (all ch.'s driven)
8 ohms per ch. (all ch.'s driven)
4 ohms per ch. (all ch.'s driven)
2 ohms per ch. (all ch.'s driven)
16 ohms Bridged per ch.
8 ohms Bridged per ch.
4 ohms Bridged per ch.
2 ohms Bridged per ch.
Performance with Gain
THD 20 Hz - 20 kHz for 1 W
THD at 1 kHz and 1 dB below clipping
Signal To Noise Ratio
Channel separation (Crosstalk) at 1 kHz
Frequency response (1 W into 8 ohms) +0/-3 dB
Input Impedance
Input Common Mode Rejection, CMR
Output impedance @ 100 Hz
Voltage Peak Limiter (VPL), max. peak output
VPL, selectable per ch. (V)
VPL, selectable when bridged (V)
1)
Voltage Peak Limiter mode (per ch.)
Gain and Level
Amplifi er gain selectable (all channels)
1)
– rear-panel switches
Default gain
Level adjustment (per ch.)
Connectors and switches
Input connectors (per ch.)
Output connectors (per ch.)
Output bridge mode per two ch.'s
NomadLink network
Intelligent fans (on/off)
Power on/off and Remote enable on/off
Cooling
front-panel indicators
Common
Per channel
Power
Operating voltage, 230 V / 115 V nominal
Minimum power-up voltage, 230 V / 115 V
Power Average Limiter (PAL)
2)
Soft start / Inrush Current Draw
Mains connector
dimensions (W/h/d)
Weight
finish
Approvals
Note 1): Automatic -6 dB gain compensation when bridging channels.
Note 2): PAL can reduce the maximum output power to keep the power supply operating safely, and/or to prevent excessive current draw tripping the mains breaker.
Refer to section 7 .5.8 Power Average Limiter (PAL) for more information.
Note 3): The amplifier will be fully operational at bridge-mode 2 ohm loads, but due to physical constraints in the construction, the max. output power will not be
significantly higher than running individual channels and therefore not stated here.
Note 4): Separate 230 V or 115 V versions available. Not selectable on the amplifier.
All specifications are subject to change without notice.
fP 14000
fP 13000
2
2
14000 W
13000 W
195 V
195 V
85 A peak
82 A peak
1200 W
1200 W
2350 W
2350 W
4400 W
4400 W
7000 W
6500 W
4700 W
4700 W
8800 W
8800 W
14000 W
13000 W
3)
3)
35 dB and VPL:
35 dB and VPL:
195 V
195 V
<0.1%
<0.1%
<0.05%
<0.05%
>112 dBA
>112 dBA
>70 dB
>70 dB
2 Hz - 34.2 kHz
6.8 Hz - 34 kHz
20 kOhm
20 kOhm
54 dB
54 dB
19 mOhm
19 mOhm
195, 170, 140,
195, 170, 140,
116, 100, 80, 66,
116, 100, 80, 66,
54 V
54 V
390, 340, 280,
390, 340, 280,
232, 200, 160,
232, 200, 160,
132, 108 V
132, 108 V
Hard / Soft
23, 26, 29, 32, 35, 38, 41, 44 dB
38 dB
35 dB
Front-panel potentiometer, 31 position detented from -inf to 0 dB
3-pin XLR, electronically balanced
Neutrik Speakon or Binding Posts (must be specified upon order). BP only on FP 14000, FP 13000, FP 9000.
A+B - Ch. A is signal input source. A+B, C+D - Ch.'s A and C are input source
2 x RJ45 EtherCon connectors, IN and OUT
Yes, depending on presence of output signal
Individual switches on front-panel
Two fans, front-to-rear airfl ow, temperature controlled speed
NomadLink network; Power Average Limiter (PAL)
Signal present / High-impedance; -20 dB, -15 dB, -10 dB and -4 dB output
signal; Voltage Peak Limiter (VPL); Current Peak Limiter (CPL):
Very High Frequency (VHF); High temperature; Fault; Mute
130-265 V / 65-135 V
4)
171 V / 85 V
Yes
Yes / max. 5 A
230 V CE: 16 A, CEE7; 115 V ETL: 30 A Twist lock | FP 4000:
W: 483 mm (19"), H: 88 mm (2 U), Overall D: 396 mm (15.6"), Mounting D: 358 mm (14.1")
12 kg (26.4 lbs.)
Black painted steel chassis with black painted steel / aluminum front
CE, ANSI/UL 60065 (ETL), CSA C22.2 NO. 60065, FCC

TEChNICAL sPECIFICATIONs 9

fP 9000
fP 7000
fP 4000
2
2
2
9000 W
7000 W
4000 W
170 V
155 V
121 V
70 A peak
59 A peak
50 A peak
800 W
730 W
400 W
1600 W
1450 W
800 W
3000 W
2800 W
1600 W
4500 W
3500 W
2000 W
3200 W
2900 W
1600 W
6000 W
5600 W
3200 W
9000 W
7000 W
4000 W
3)
3)
3)
35 dB and VPL:
35 dB and VPL:
35 dB and VPL:
170 V
155 V
121 V
<0.1%
<0.1%
<0.1%
<0.05%
<0.05%
<0.05%
>112 dBA
>112 dBA
>112 dBA
>70 dB
>70 dB
>70 dB
2 Hz - 34.2 kHz
6.8 Hz - 34 kHz
2 Hz - 34.2 kHz
20 kOhm
20 kOhm
20 kOhm
54 dB
54 dB
54 dB
19 mOhm
19 mOhm
32 mOhm
170, 140, 116,
155, 121, 101,
121, 101, 83, 70,
10 0,
8 0,
6 6,
83, 70, 56, 47,
56, 47, 38 V
54 V
38 V
340, 280, 232,
310, 242, 202,
242, 202, 166,
200, 160, 132,
166, 140, 112,
140, 112, 9 4,
108 V
94, 76 V
76 V
38 dB
35 dB
35 dB
; Power on
2)
230 V CE: 16 A, CEE7; 115 V ETL: 20 A / NEMA 5-20P
FP+ Series Operation Manual 35
fP 10000q
fP 6000q
4
4
10000 W
6000 W
150 V
101 V
54 A peak
38 A peak
660 W
320 W
1300 W
625 W
2100 W
1250 W
2500 W
1500 W
2600 W
1250 W
4200 W
2500 W
5000 W
3000 W
3)
3)
35 dB and VPL:
35 dB and VPL:
150 V
101 V
<0.1%
<0.1%
<0.05%
<0.05%
>112 dBA
>112 dBA
>70 dB
>70 dB
6.8 Hz - 34 kHz
6.8 Hz - 34 kHz
20 kOhm
20 kOhm
54 dB
54 dB
32 mOhm
32 mOhm
150, 121, 101,
101, 83, 70, 56,
83, 70, 56, 47,
47, 38 V
38 V
300, 242, 202,
202, 166, 140,
166, 140, 112,
112, 94, 76 V
94, 76 V
35 dB
35 dB

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp9000Fp13000Fp7000Fp4000Fp10000qFp6000q ... Show all

Table of Contents