The following tables contain information on measured current consumption as well as calculated heat dissipation during normal operation
(1/8 rated power); and during extreme heavy duty operation (max power).
Level
Load
Standby with remote power off via Nomadlink
Power on, Idling
Pink noise
16 Ω / Ch.
(1/8th rated
32 Ω / Bridged
power)
8 Ω / Ch.
16 Ω / Bridged
4 Ω / Ch.
8 Ω / Bridged
2 Ω / Ch. *4)
4 Ω / Bridged *4)
Pink noise
16 Ω / Ch.
(max power)
32 Ω / Bridged
*3)
8 Ω / Ch.
16 Ω / Bridged
4 Ω / Ch.
8 Ω / Bridged
2 Ω / Ch.
4 Ω / Bridged
Mains connector, 230 V CE version
Mains connector, 115 V ETL version
*1) The amplifi er's PSU operates as a non-resistive load, so the calculation "Volts x Amps = Watts" would not be correct. Instead, measured and specifi ed here
is what is known as the "Active Power" of the amplifi er providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw fi gures measured at 230 V. 115 V fi gures are 230 V fi gures multiplied by two.
*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation . Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is
momentarily in excess of max. ratings.
*4) Italics used for conditions that, if sustained over long time periods, may trigger the mains breaker. Therefore these measurements should not be used when
calculating cooling requirements as they cannot be sustained by the mains breaker over time.
Table 8.4f: FP 10000Q Current Draw and Thermal Dissipation specifications
I N T E R N A T I O N A L C O N T A C T ▸ I N F O @ L A B G R U P P E N . C O M
-10dB
A
channel
HI-IMP
SIG -20 -15 -10 -4
-inf
0
-10dB
BRIDGE A+B
B
channel
SIG -20 -15 -10 -4
HI-IMP
-inf
0
FP1 0000Q
-10dB
C
channel
HI-IMP
SIG -20 -15 -10 -4
-inf
0
BRIDGE C+D
-10dB
D
SIG -20 -15 -10 -4
channel
HI-IMP
-inf
0
FP 10000Q
Rated Power
Line Current *2)
120 VAC
230 VAC
®
Amp (I)
660
x 4
10.7
5.6
1320
x 2
1300
x 4
16.9
8.8
2600
x 2
2100
x 4
25.9
13.5
4200
x 2
2500
x 4
32.2
16.8
5000
x 2
660
x 4
13.6
1320
x 2
1300
x 4
22.4
11.7
2600
x 2
2100
x 4
30.0
16.0
4200
x 2
2500
x 4
30.0
16.0
5000
x 2
16 A, CEE7
30 A, Twist lock
L A B . G R U P P E N A B ▸ S W E D E N
W W W . L A B G R U P P E N . C O M
CLIP
VHF
VPL CPL
TEM
MUTE
PWR
VPL CPL
VHF
TEM
CLIP
PAL
CLIP
VHF
VPL CPL
TEM
NOMAD
LINK
MUTE
VPL CPL
VHF
TEM
CLIP
Watt *1)
In
Out
0
0
139
0
Watt
732
330
1224
650
1914
1050
2414
1250
7.1
1143
880
2096
1733
2377 / 2455
1466 / 1542
2237 / 2291
1099 / 1145
U S & C A N A D A C O N T A C T ▸ I N F O @ T C G - A M E R I C A S . C O M
|
APPENDIX 8
POW
FP SERIES
POW
Thermal dissipation
Dissipated
BTU/hr
kCal/hr
0
0
139
475
402
1371
574
1958
864
2949
1164
3973
263
897
363
1238
910 / 914
3107 / 3118
783 716
1139 / 1146
3886 / 3911
979 / 985
Item no. CDTD_FP10000Q_V5
FP+ Series Operation Manual 33
R
0
120
345
493
743
1001
226
312

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp9000Fp13000Fp7000Fp4000Fp10000qFp6000q ... Show all

Table of Contents