Maintenance And Inspection - Hitachi C12LCH Handling Instructions Manual

Compound miter saw
Table of Contents

Advertisement

Spindle Lock
17 mm Box Wrench
Saw Blade
Bolt
Washer (B)
CAUTION
Confirm that the spindle lock has returned to the
retract position after installing or removing the saw
blade.
Tighten the bolt so it does not come loose during
operation.
Confirm that the bolt has been properly tightened
before the power tool is started.
2. Dismounting the saw blade
Dismount the saw blade by reversing the mounting
procedures described in paragraph 1 above.
The saw blade can easily be removed after lifting the
lower guard.
CAUTION
Never attempt to install saw blades except
290 mm – 305 mm in diameter.
12
Fig. 27
Bolt
Washer (B)
Fig. 28
Washer (A)
Fig. 29

MAINTENANCE AND INSPECTION

WARNING
To avoid an accident or personal injury, always
confirm the trigger switch is turned OFF and that the
power plug has been disconnected from the
receptacle before performing any maintenance or
inspection of this tool.
1. Inspecting the saw blade
Always replace the saw blade immediately upon the
first sign of deterioration or damage.
A damaged saw blade can cause personal injury and
a worn saw blade can cause ineffective operation and
possible overload to the motor.
CAUTION
Never use a dull saw blade. When a saw blade is dull,
its resistance to the hand pressure applied by the tool
handle tends to increase, making it unsafe to operate
the power tool.
2. Inspecting the lever (Fig. 30 and Fig. 31)
If the M8 hexagonal head bolts (2) are loose, align the
sides of the fence and saw blade with the steel square.
After adjusting the saw blade and fence to a ninety-
degree angle, tighten the lever securing hexagonal
head bolts (2).
Lever
Hex. Head Bolt
Saw Blade
Fence (B)
Steel Square
3. Inspecting the carbon brushes
For your continued safety and electrical shock
protection, carbon brush inspection and replacement
on this tool should ONLY be performed by a Hitachi
Authorized Service Center.
4. Replacing supply cord
If the supply cord of Tool is damaged, the Tool must
be returned to Hitachi Authorized Service Center for
the cord to be replaced.
Fig. 30
Fig. 31

Hide quick links: