Download Print this page

HP BladeSystem c7000 Quickspecs page 15

Hp bladesystem c7000 enclosure
Hide thumbs Also See for BladeSystem c7000:

Advertisement

QuickSpecs
Configuration Information Factory Integrated Models
HP Cooling Options
Step 3: Select optional software bundle (if nothing is selected system will ship with 16
Insight Control Trial Licenses):
HP Insight Software
Step 4: Select optional Redundant BladeSystem Onboard Administrator Capability
HP c-Class Enclosure
Options
HP 2250W -48VDC Hot Plug Power Supply Kit
NOTE: This option disables HP Power Discovery Services.
NOTE: Only compatible with -48V DC Power Input Module.
c-Class Active Cool Fan (Up to 6)
HP BLc 6X Active Cool 200 Factory Integrated Fan Option
NOTE: The bundle includes a quantity of 6 HP Active Cool 200 Fans so a full enclosure
can be configured with a single part number.
HP BLc7000 Enclosure HP Single Active Cool Fan Option Kit
NOTE: A minimum of 4 Active Cool 200 Fans is required, 8 Active Cool 200 Fans can
support a full blade enclosure, 10 Active Cool 200 Fans should be ordered for reduced
power consumption and noise reduction.
NOTE: Single-phase models may require additional power supplies. Fans should be
added to provide redundancy, reduce power consumption and reduce noise.
NOTE: Three-phase models require a minimum of 6 Active Cool 200 Fans.
NOTE: Some blade configurations require 10 fans.
Enclosure Options
HP Insight Control for BladeSystem including 1yr 24x7 Support Enclosure 8 Svr FIO
Electronic License
NOTE: This license supports HP ProLiant c-Class blade servers.
NOTE: Must be purchased as an option to an HP BladeSystem enclosure. FIO can only be
ordered as part of a factory-configured platform. Customer will receive a printed
license entitlement certificate via physical shipment.
HP BLc7000 Onboard Administrator with KVM Option
NOTE: The HP c7000 OA supports the mixing with the HP c7000 OA with KVM. The HP
c7000 OA with KVM must be the active OA to provide the enclosure KVM feature. The
KVM menu has an OA CLI button at the bottom, which allows an OA administrator to log
into the OA and be able to force a takeover so the OA with KVM will become the standby
OA. The OA Firmware Sync feature cannot be used to update mismatched OA modules.
Mismatched OA firmware versions between the original c7000 OA and c7000 OA with
KVM require the administrator to use the GUI or CLI to update the OA from a file (http,
ftp, tftp, local client file using the GUI or USB key containing the OA firmware file).
NOTE: Models of the c7000 enclosure (part numbers 681844-B21 and AD361D) come
with a BladeSystem Onboard Administrator with KVM as standard. Order this part
number (456204-B21) when a second redundant BladeSystem Onboard Administrator
is desired for a c7000 enclosure.
NOTE: HP ProLiant Gen8 server blades and certain options require the latest version of
the Onboard Administrator firmware. This firmware release may also require other
subsystem firmware upgrades. For information on the latest firmware versions, please
see the Blades Firmware Maintenance website at:
http://h18004.www1.hp.com/products/blades/components/c-class-compmatrix.html.
DA - 12810 Worldwide — Version 52 — December 10, 2013
HP BladeSystem c7000 Enclosure
AH332A
517520-B21
412140-B21
C6N32ABE
456204-B21
Page 15