Intel® Storage Server SSR212MC2
8.3
Environmental Limits
The following table summarizes environmental limits, both operating and non-operating.
Table 21: Operating and Non-Operating Environmental Limits
Temperature
Non-operating
Operating Temperature
Thermal Map
Thermal Shock
Non-operating
Humidity
Non-operating
Vibration
Non-Operating:
Shock
Non-operating
ESD
Operating
EMI
Operating
Revision 1.2
Specification
-40 degrees celcius to 70 degrees celcius
10 degrees celcius to 35 degrees celcius
Must not exceed maximum Integrated Circuit (IC) junction temperature as specified
in the component data sheets (CPDs).
Specification
-40 degrees celcius to 70 degrees celcius
Specification
92% Relative Humidity (RH) at +50 degrees celcius
Specification
2.2 Grms 5-500Hz for the unpackaged and 1.09 Grms 5-500Hz for the
packaged.
Specification
25 G, 11 millisecond (msec)
Specification
Test (air) to 15 KV and (contact) to 2-8KV with limited errors.
Specification
Required to meet EMI emission requirements, tested as part of system.
Environmental Limits
35
Need help?
Do you have a question about the SSR212MC2 - Storage Server Hard Drive Array and is the answer not in the manual?
Questions and answers