Materials List; Operation; Specifications & Dimensions - Aprilaire 850 Installation & Maintenance Instructions Manual

Steam humidifier fan pack
Table of Contents

Advertisement

MaTeRIalS lIST

MaTeRIalS FURnISHeD
Model 850 Fan Pack
Digital manual humidistat
4 housing mounting screws
2 tap connectors
2 wire ties

oPeRaTIon

On a call for humidity the Model 800 Residential Steam Humidifier provides power to the Model 850 Fan Pack . The Model 850 blower distributes
the steam to the room . When the call for humidity ends and the humidifier stops producing steam, the Model 850 Fan Pack will continue to
operate for 2 minutes to distribute the remaining steam before de-activating .
SPeCIFICaTIonS & DIMenSIonS
TeCHnICal SPeCIFICaTIonS
• 24 VAC supplied by Model 800 humidifier
• Stainless steel steam dispersion chamber
• Noise dampening housing liner
• Ultra quiet fan
2 grille mounting screws
Neoprene condensation tubing – 3/8" ID, 10'
20VA Transformer
Relay
DIMenSIonS
FIGURe 1 – Dimensions of the Model 850
Fan
Inlet
90-1554
noT FURnISHeD
Steam hose – 6' steam hose provided with the Model 800
humidifier
Steam hose clamp – provided with the Model 800 humidifier
Wire for humidistat and wire to power Model 850 Fan Pack
14
17-1/16
Fan Outlet
5
4-3/4
7-13/16
6-1/16
3/8
Steam Dispersion
Manifold
7-1/16
6-7/8
3