PHP900DM
GE Profile
30" Electric Induction Cooktop
™
Dimensions and Installation Information (in inches)
Note: Check local codes for required breaker size
†
KW Rating
Important: Requires a 5" free area between
240V
8.6
the bottom of the cooktop to any combustible
208V
6.5
material, i.e., shelving. Free area not required
when installing wall oven underneath cooktop.
Breaker Size
Refer to installation instructions. Requires a
240V
40 Amps
15" minimum from cooktop to adjacent
†
overhead cabinets. Units are furnished with
208V
40 Amps
†
a 36" flexible armored cable.
Note: 36" Ribbon cooktops are approved for use over GE 30" Single Wall
Ovens and Warming Drawers only. Refer to cooktop and wall oven/
warming drawer installation instructions packed with product for current
dimensional data. If installed with a GE Profile
consult both the cooktop and downdraft installation instructions packed with
product before installing. Cooktop gas/electric supply may need to be
re-routed to install downdraft. The countertop must be at least 26" deep
with a flat surface area of 23-1/2" or more, front to back. In addition,
other clearances to the front edge of the countertop must be considered,
especially on raised bullnose countertops. Consult cabinet and countertop
manufacturer's specs for flush mount installation prior to install.
Installation Information: Before installing, consult installation instructions
packed with product for current dimensional data.
For answers to your Monogram,
®
GE
appliance questions, visit our website at
®
ge.com or call GE Answer Center
800.626.2000.
Telescopic Downdraft System,
™
GE Profile
™
or
service,
®
21-3/8
29-3/4
Cooktop
19-5/8
28-1/2
2-1/2**
Required
* Depth of unit at conduit connection location (rear) is
6-1/2" on models PP980/950 and 4-5/8" on models
PHP900/PP975/972/962/945/942/932/912,
JP655/356/346.
**Raised bull nose countertops may require up to
3/8" additional clearance to prevent interference
with curved front.
30_color_cktp_install.eps
13" MAX.
depth
3-1/4*
30" MIN. to
unprotected
cabinet
15" MIN.
to cabinet
1-3/4" to
rear wall
1-1/2" MIN.
clearance to
side wall
from cut-out
Electrical junction box 16" MIN.
below countertop
Specification Revised 9/07
1-1/2" MIN.
clearance to
side wall
from cut-out
Cut should
not interfere
with cabinet
structure
at front
Listed by
Underwriters
Laboratories
220580