Ariston microGENUS II 24 MFFI Installation And Servicing Instructions page 7

Type c boilers
Hide thumbs Also See for microGENUS II 24 MFFI:

Advertisement

F
. 2.3
IG
secure with the wall screws supplied, assemble the
connection kit and secure to the wall. N
recommended that a spirit level be used to position the
appliance to ensure that it is perfectly level.
2.5.2.
Position the appliance on the hanging bracket
and connect the connection kit to the boiler connections.
(see also Sections 2.7 Gas Connections, 2.8 Water
Connections & F
. 2.3).
IG
2.6
E
C
LECTRICAL
ONNECTION
For safety purposes, have a competent person carefully
check the electrical system in the proper ty, as the
manufacturer will not be held liable for damage caused by
the failure to earth the appliance properly or by anomalies
in the supply of power. Make sure that the residential
electrical system is adequate for the maximum power
absorbed by the unit, which is indicated on the rating
plate. In addition, check that the section of cabling is
appropriate for the power absorbed by the boiler.
The boiler operates with alternating current, as indicated
in the Technical Information table in Section 10, where the
maximum absorbed power is also indicated. Make sure
that the connections for the neutral and live wires
correspond to the indications in the diagram. The
appliance electrical connections are situated on the
reverse of the control panel.
I
!
MPORTANT
In the event that the power supply cord must be changed,
replace it with one with the same specifications.
Note: The diagrams for the electrical system are indicated
in section 2.13.
Warning, this appliance must be earthed.
External wiring to the appliance must be correctly earthed
and polarised and must be carried out by a competent
person in accordance with relevant regulations and rules,
in GB reference should be made to the current I.E.E.
Regulations and applicable local regulations, in Scotland,
the electrical provisions of the Building Regulations
applicable in Scotland, and for IE the current edition of
I.S. 813 and the current ETCI rules.
The appliance is supplied with a fly-lead already
connected, this must be connected to a 220-240v supply
fused at 3A and must facilitate complete electrical
isolation of the appliance, by the use of a fused double
pole isolator having a contact separation of at least 3 mm
in all poles or alternatively, by means of a 3 A fused
three pin plug and unswitched shuttered socket outlet
both complying with BS 1363.
The point of connection to the Electricity supply must be
readily accessible and adjacent to the appliance unless
the appliance is installed in a bathroom when this must
be sited outside the bathroom (see section 2.2).
Should external controls be required, the design of the
external electrical circuits should be undertaken by a
competent person, see Section 2.13 for fur ther
information.
: It is highly
OTE
7