Sagem 1201 Quick Installation Manual

F@st modem
Hide thumbs Also See for 1201:

Advertisement

Quick Links

SAGEM F@st
1201/1241 V2
TM

Quick Installation Guide

253156400-A_GIR 1201 V2 STD-gb.i1 1
14/10/2008 16:59:35

Advertisement

Table of Contents
loading

Summary of Contents for Sagem 1201

  • Page 1: Quick Installation Guide

    SAGEM F@st 1201/1241 V2 Quick Installation Guide 253156400-A_GIR 1201 V2 STD-gb.i1 1 14/10/2008 16:59:35...
  • Page 2: Table Of Contents

    2.2 ConneCting additional telephones .......... 3 InSTALLATIon FRoM ThE CD-RoM ........4 3.1 installation on the ethernet port ........... 3.2 installation on the usB port............3.3 reinstalling or uninstalling your modem ......4 TRoUbLEShooTInG ............9 4.1 status of the leds on the front ..........4.2 modem supervision ................ 4.3 «diagnostiCs» tool ................ 5 SAFETY InSTRUCTIonS ..........13 5 SAFETY InSTRUCTIonS (ConTD.) ........14 253156400-A_GIR 1201 V2 STD-gb.i2 2 14/10/2008 16:59:35...
  • Page 3 SAGEM F@st™ 1201/1241 V2 sagem Ciomlmunications thanks you for choosing the range of sagem f@st 1201/1241 v2 modems while hoping that it will provide you with full satisfaction. sagem f@st 1201 v2 and sagem f@st 1241 v2 products adapt the adsl func- tion respectively on pots (itu g.992.1/3/5 - appendix a) and on isdn (itu g.992.1/3/5 - appendix B). sagem f@st 1201 v2 and sagem f@st 1241 v2 equipment include an ethernet interface (eth) and an usB interface. sagem f@st 1201 v2 and sagem f@st 1241 v2 products can be provided in «bridged» or «Routed» version according to the isp. in addition, this modem will provide you with access to all the services provided by your isp (Internet Service provider), as shown in the diagram below. List of symbols used in this guide Warns you about an action or a serious omission. provides you with important information you must take into account. presentation 253156400-A_GIR 1201 V2 STD-gb.i3 3 14/10/2008 16:59:45...
  • Page 4: Contents Of The Pack

    SAGEM F@st™ 1201/1241 V2 1 ConTEnTS oF ThE pACk Before you start the installation make sure that the pack contains the following items: note: The modem can be either in white or black colour Contents of the pack 253156400-A_GIR 1201 V2 STD-gb.i4 4 14/10/2008 16:59:47...
  • Page 5: Connecting Your Modem

    SAGEM F@st™ 1201/1241 V2 2 ConnECTInG YoUR MoDEM 2.1 ConnECTInG YoUR RoUTER make sure that the modem is not connected to your computer before you start the installation from the Cd-rom. follow the procedure according to the stages described in the Cd-rom installation and connect your telephone in accordance with the drawing below: 2.2 ConnECTInG ADDITIonAL TELEphonES make the connections according to the diagram opposite. Connection 253156400-A_GIR 1201 V2 STD-gb.i5 5 14/10/2008 16:59:48...
  • Page 6: Installation From The Cd-Rom

    SAGEM F@st™ 1201/1241 V2 3 InSTALLATIon FRoM ThE CD-RoM make sure that the modem is not connected to your computer before you start the installation from the Cd-rom. the installation procedure described below was undertaken in Windows vista installation in other Windows® (98, me, 2000 and Xp) can be slightly different.  insert the Cd-rom into the relevant drive; the screen oppo- site will appear:  click on next.  the screen opposite describes the precautions to be taken during the installation.  click on next. Installation from the CD-RoM 253156400-A_GIR 1201 V2 STD-gb.i6 6 14/10/2008 16:59:51...
  • Page 7 SAGEM F@st™ 1201/1241 V2 the screen opposite will appear. select the mode of connection that you wish (ethernet or usB) to connect your modem to your computer. Installation from the CD-RoM 253156400-A_GIR 1201 V2 STD-gb.i7 7 14/10/2008 16:59:52...
  • Page 8: Installation On The Ethernet Port

    Ethernet cable», click on next. follow the instructions provided by the install screens by pluging in the modem supply, switching it on and connecting the adsl line and then connect the modem to your computer using the yellow ethernet cable. once you have made these connections, an internet connection screen will appear. you must enter your username then your connection password. this information is provided by your Internet Service provider (isp). Once you have entered the configuration parameters, a window will appear listing the different steps in the installation. once all these steps are complete, an end of the installation window will appear telling you that your modem has been correctly installed. Click on finish. you may now use your internet access. the "http://sagem-communications.com" site will open. Installation from the CD-RoM 253156400-A_GIR 1201 V2 STD-gb.i8 8 14/10/2008 16:59:58...
  • Page 9: Installation On The Usb Port

    USb cable», click on next. follow the instructions provided by the install screens by pluging in the modem supply, switching it on and connecting the adsl line and then connect the modem to your computer using the blue usB cable. once you have made these connections, an internet connection screen will appear. you must enter your user name then your connection password. this information is provided by your Internet Service provider (isp). Once you have entered the configuration parameters, a window will appear listing the different steps in the installation. once all these steps are complete, an end of the installation window will appear telling you that your modem has been correctly installed. Click on finish. you may now use your internet access. the "http://sagem-communications.com" site will open. Installation from the CD-RoM 253156400-A_GIR 1201 V2 STD-gb.i9 9 14/10/2008 17:00:03...
  • Page 10: Reinstalling Or Uninstalling Your Modem

    SAGEM F@st™ 1201/1241 V2 3.3 REInSTALLInG oR UnInSTALLInG YoUR MoDEM if your installation failed or that you want uninstall your modem, insert again your Cd-rom in the relevant drive; the following screen will appear: Click on «You want to configure your modem»" or «you want to uninstall your modem» according to your choice, then follow the instructions displayed on the screen. Installation from the CD-RoM 253156400-A_GIR 1201 V2 STD-gb.i10 10 14/10/2008 17:00:04...
  • Page 11: Troubleshooting

    Troubleshooting 253156400-A_GIR 1201 V2 STD-gb.i11 11 14/10/2008 17:00:04...
  • Page 12: Modem Supervision

    LEDs Green adsl line synchronised yellow adsl line synchronising adsl line not connected Connected public address (Wan) distributed to Green the modem yellow Waiting for ISp adsl line synchronising Adsl Down public address (Wan) not distributed to the modem or adsl line not conneted Not configured no vC (virtual Channel) Router rebooting modem is rebooting Access denied erroneous login and/or password bit rate displays the nominal downlink bit rate displays the nominal uplink bit rate Troubleshooting 253156400-A_GIR 1201 V2 STD-gb.i12 12 14/10/2008 17:00:05...
  • Page 13: Diagnostics» Tool

    SAGEM F@st™ 1201/1241 V2 buttons update the data displayed on the screen reboot your modem 4.3 «DIAGnoSTICS» TooL to access this tool:  open the configuration tool (see the modem supervision section).  select the “Status” heading then the “Diagnostics” menu in the relevant list located in the left of each window, the following screen woll appear: Troubleshooting 253156400-A_GIR 1201 V2 STD-gb.i13 13 14/10/2008 17:00:07...
  • Page 14: Connection Status

    HTTP configu- ration tool’s welcome page. Returning to the factory configuration To return to the factory configuration:  in the top left of your HTTP configuration tool’s welcome page select the Management heading then the Restore Default sub-menu in the Settings menu.  or press and hold for about 15 seconds on the button marked «RESET» on the back of your modem. Troubleshooting 253156400-A_GIR 1201 V2 STD-gb.i14 14 14/10/2008 17:00:07...
  • Page 15: Safety Instructions

    16 A overcurrent protection and differential protection.  the modem should be connected to the mains via a readily accessible wall socket ensuring the electric cutting. Maintenance  It is prohibited to open the casing. This must be done only by qualified personnel appro- ved by your supplier.  do not use liquid or aerosol cleaning agents. Safety instructions 253156400-A_GIR 1201 V2 STD-gb.i15 15 14/10/2008 17:00:08...
  • Page 16: Safety Instructions (Contd.)

    Safety level primary power source access hpv (hazardous primary Voltage circuit) Bipolar aC mains socket dC power supply access selv (Safety Extra Low Voltage) Miniature fixed connector (Power) type B usB access (usB) selv rJ45 ethernet access (ethernet) selv rJ11 line access (line) tnv3 (Telecommunication network Voltage level 3 circuit) products bearing this symbol comply with emC regulations as well as the low voltage directive published by the Commission of the European Community (CeC). EC Declaration EC compliance declaration Sagem Communications declares that the product named sagem f@st™ 1201 v2 or sagem f@st™ 1241 v2 complies with the demands of the european Community directi- ves 1995/5/eC as well as with the essential demands of the directives 89/336/eeC dated 03/05/1989 and 73/23/eeC dated 19/02/1973. the eC compliance declaration for the sagem f@st™ 1201 v2 and sagem f@st™ 1241 v2 is implemented within the framework of the r&tte directive. Safety instructions 253156400-A_GIR 1201 V2 STD-gb.i16 16 14/10/2008 17:00:08...
  • Page 17 SAGEM F@st™ 1201 V2 notes:_____________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ _________________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ _________________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ 253156400-A_GIR 1201 V2 STD-gb.i17 17 14/10/2008 17:00:08...
  • Page 18 ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ Registered trademarks sagem f@st is a registered trademark of Sagem Communications. sagem is a registered brand of safran group. ® mac os is a registered trademark of apple Computer, inc. ® Windows is a registered trademark of microsoft Corporation. Copyright Sagem Communications document. reproduction and disclosure prohibited. 253156400-A_GIR 1201 V2 STD-gb.i18 18 14/10/2008 17:00:08...
  • Page 19 Tél. : +33 1 58 11 77 00 - Fax : +33 1 58 11 77 77 http://www.sagem-communications.com Société Anonyme au capital de 158 291 895 euros - 440 294 510 RcS Paris 253156400-A_GIR 1201 V2 STD-gb.i19 19 14/10/2008 17:00:09...

This manual is also suitable for:

1241 v2F@st 1201F@st 1241 v2

Table of Contents