Bosch NDC-265-P Installation And Operation Manual page 88

200 series ip camera
Hide thumbs Also See for NDC-265-P:
Table of Contents

Advertisement

88
en | Advanced Mode
A special IP address (class D address) must be configured for
multicast operation in a multicast-enabled network. The
network must support group IP addresses and the Internet
Group Management Protocol (IGMP V2). The address range is
from 225.0.0.0 to 239.255.255.255. The multicast address can
be the same for multiple streams. However, it is then necessary
to use a different port in each case so that multiple data
streams are not sent simultaneously using the same port and
multicast address. The settings must be made individually for
each stream.
Enable
Enable simultaneous data reception on several receivers that
need to activate the multicast function. To do this, check the
box and then enter the multicast address.
Multicast Address
Enter a valid multicast address to be operated in multicast
mode (duplication of the data stream in the network). With the
setting 0.0.0.0 the encoder for the stream operates in multi-
unicast mode (copying of data stream in device). The camera
supports multi-unicast connections for up to five
simultaneously-connected receivers.
Duplication of data places a heavy demand on the CPU and can
lead to impairment of the image quality under certain
circumstances.
Port
Enter the port address for the stream here.
Streaming
Click the checkbox to activate multicast streaming mode. An
activated stream is marked with a check. (Streaming is typically
not required for standard multicast operation.)
Multicast packet TTL
A value can be entered to specify how long the multicast data
packets are active on the network. If multicast is to be run via a
router, the value must be greater than 1.
AR18-10-B012 | v1.5 | 2011.01
Installation and Operation Manual
IP Camera 200 Series
Bosch Security Systems

Hide quick links:

Advertisement

Table of Contents
loading