Download Print this page

Table Of Contents; Unpacking; Service; Site Preparation - Bosch LTC9316/00P Installation Manual

Standard pole

Advertisement

LTC9316/00P

Table of Contents

1 DESCRIPTION
4 4 INSTALLATION
The LTC 9316/00P units are 16 foot steel mounting poles for
use with Unity® Domes, AutoDomes®, and the LTC 9320
Series of Outdoor Fixed Domes.

2 UNPACKING

Unpack carefully. This is mechanical equipment and should be
handled with care.
Check for the following:
• Packet Assembly for LTC 9316/00P:
1 Bosch Adapter Plate.
4 3/8 x 1-in Stainless Steel Hex Head Bolt.
4 5/16-18 Stainless Steel Hex Nut.
4 5/16 Stainless Steel Flat Wash.
4 3/8 Stainless Steel Split Lockwasher.
4 5/16 Stainless Steel Split Lockwasher.
1 Wiring grommet
1 Conduit plug
1 Installation Instructions (This Manual).
• Steel Pole
If an item appears to have been damaged in shipment, replace it
properly in its carton and notify the shipper. If any items are
missing, notify your Bosch Security Systems Sales
Representative or
Customer Service.
The shipping carton is the safest container in which the unit
may be transported. Save it for possible future use.

3 SERVICE

If the unit ever needs repair service, the customer should
contact the nearest Bosch Security Systems Service Center for
authorization to return and shipping instructions.
Service Centers
U.S.A.: Phone: 800-366-2283 or 408-956-3895
fax:
800-366-1329 or 408-956-3896
e-mail: NationalServiceCenter@ca.slr.com
Canada: 514-738-2434
Europe, Middle East & Asia Pacifi c Regions:
32-1-440-0711
For additional information, see www.boschsecuritysystems.com
Bosch Security Systems
10 October 2003
Instruction Manual
Introduction
4 INSTALLATION
This installation should be made by qualifi ed service personnel and
conform to the National Electrical Code and applicable local codes.
Please read these instructions carefully before proceeding, and
!
heed all cautions.
4.1

Site Preparation

NOTE: Special attention must be paid to the size of the
!
wiring conduit and its location within the concrete
foundation and jig (if applicable). The Wiring
Conduit can be up to 2" in diameter. Use reducers
if necessary. Also, make sure that the Wiring
Conduit is in the center of the foundation and
Anchor Jig during installation (Figure 1).
Up to 2-inch
in Diameter
Figure 1 Mounting Bolts & Wiring Conduit Location
1. Select a suitable site for the LTC 9316/00P and prepare the pad site
using a hole 36" x 36" x 36" deep. The top of the concrete
foundation should be fl ush with the ground.
CAUTION: Be sure that there are no underground electric or
!
phone cables or gas or water lines in the area where the pole
will be located.
2. To help reinforce the concrete foundation, place (12) 1/2" diameter
x 32" long Reinforcement Bars (rebar) as shown in Figure 2. Use
suitable preparation methods to place the rebar.
E
2
N
2
2
2
3
3
3
4
Mounting
Bolts
Wiring
Conduit

Advertisement

loading