Connection Sequence - C900V2 And; Without Telephone Line) - Bosch Conettix C900V2 Installation Manual

Dialer capture ethernet module
Hide thumbs Also See for Conettix C900V2:
Table of Contents

Advertisement

Conettix C900V2 | Installation Guide | 6.0
.
Table 10: Connection Sequence – C900V2 and Generic Control Panel in Separate Enclosures
(UL Standard 1610, with or without Telephone Line)
Seq
C900V2 Connection
1
RJ-45 PANEL connector
2
RJ-45 ETHERNET
connector
3
– V terminal
4
V +
5
Install an EOL resistor for
the control panel across
OUT2-L and OUT1-R
6
OUT2-L TO OUT1-L
7
OUT2-R TO OUT1-R
8
OUT1-R
9
10
11
OUT2-L
12
13
14
15
NOTE: The sequence numbers appear in the diagram in Figure 12.
The optional telephone line is for programming and diagnostics only.
Bosch Security Systems, Inc. | 8/08 | F01U087780-01
UL Standard 1610 and ULC S304 Intrusion System Installations
Control Panel Connection
to
RJ-45 connector (telco dialer)
to
to
–12 to –24 VDC (common)
to
+12 to +24 VDC output
to
24-hour zone input common
to
24-hour zone input
Battery negative input
Battery positive input
AC input
AC input
Other Connection
LAN or WAN
C900V2 enclosure closed-circuit
tamper switch
C900V2 enclosure closed-circuit
tamper switch to control panel
enclosure closed-circuit tamper
switch
to
Control panel enclosure closed-
circuit tamper switch
to
Battery negative terminal
to
Battery positive terminal
AC transformer
AC transformer
21