The IP and MAC addresses in this
procedure are examples and are not the
same as those for your C900V2.
1. Select Start
Run.
The Run dialog box appears.
2. In the Run dialog box, type COMMAND and
click OK.
A DOS window appears:
3. At the DOS command line, type:
arp -s xxx.xxx.xxx.xxx zz-zz-zz-zz-zz-zz
and press [ENTER].
xxx.xxx.xxx.xxx is the IP address the
network administrator assigned to the
C900V2
zz-zz-zz-zz-zz-zz is the MAC address
printed on the Ethernet connector label.
For example:
The program responds with a prompt to
indicate that the address was accepted.
The program does not indicate that the
operation was performed properly. The
only indication is the absence of an
error message.
4. Verify that you entered the IP address
correctly. Type:
arp -g
and press [ENTER].
This command displays the IP address
172.17.10.70 temporarily linked to MAC address
00-20-4a-12-04-0e as shown in Figure 11. The
temporary link shows a static entry.
14
C900V2 Configuration Setup Instructions

Figure 11: ARP Table

The network uses this table to identify devices and
to route signals. The number of devices and other
types (static and dynamic, as shown in the
example) depends on the network and the number
and type of devices with which this PC
communicates. Identify the MAC address of the
device you are installing and verify that it now has
an IP address linked to it.
4.5
Using Telnet to Finish the
Configuration
Use the telnet program to configure the C900V2.
The procedure for Windows 98SE, ME is different
from the procedure for Windows 2000 and
Windows XP.
4.5.1

Starting Windows 98SE, ME Telnet

1. Select Start
The Run dialog box appears.
2. In the Run dialog box, type telnet and press
[ENTER].
The Telnet application window appears.
3. Select Connect
The Connect dialog box appears.
a. In the Host Name field, type the IP
address of the C900V2.
b. In the Port, field type 1.
c. Accept vt100 as the TermType field.
d. Click Connect.
Bosch Security Systems, Inc. | 8/08 | F01U087780-01