Download Print this page

Xantech WL85 Installation Instructions page 4

Wall link plasma, lcd, led, cfl friendly ir receiver
Hide thumbs Also See for WL85:

Advertisement

Figure 5 – Interfacing STATUS connection of WL85 with Zone STATUS
line on ZPR68-10
7
In Single Zone systems, the Status LED could show the ON/OFF status of
an AV Receiver. To achieve this, simply plug a 12vDC adapter, such as the
Xantech 781ERGPS Power Supply, into the switched AC Outlet of the AV
Receiver. The 12v '+' and '-' leads are then connected between the
STATUS ('+' lead) and GND ('-' lead) terminals of the WL85. The
Connecting Block makes a convenient tie-line for extending leads of the
Power Supply to the actual terminals of the WL85 as shown in Figure 6.
WL Series
J-Box
IR Receiver
(rear view)
+12V
+12VDC
STATUS
Hand Held
ST A TUS
GND
GND
Remote
IR OUT
IROUT
Add resistor in series
4- conductor
with STATS line to
inter-room cable
adjust brightness, if desired.
(unshielded OK)
.
(see text, next page)
REMOTE ROOM
Figure 6 – Interfacing STATUS connection of WL85 to Switched Outlet
of AV Receiver
781ERGPS
Satellite Receiver
T o 120 VAC
(unswitched)
Emitter
Plug into
789-44
DVD
Switched AC Outlet
Connecting Block
on A/V Receier
(see text)
Emitter
A/V Receiver
+12VDC
786-00
GND
ST ATUS
Power supply
IR IN
(12V at 10mA)
+
Emitter
White Striped Side ("+")
MAIN ROOM
8

Advertisement