J. Startup
All parts are factory-adjusted. Improper adjustments may adversely affect safety,
performance, component life, and warranty coverage.
• If the appliance is turned off, wait for at least 3 minutes before restarting the
appliance to prevent damage to the compressor.
• At startup, confirm that all internal and external connections are free of leaks.
• On remote models, the appliance must have power for a minimum of 4 hours prior
to startup to prevent compressor damage.
1) Open the water supply line shut-off valve(s).
2) Remove the front panel.
3) Move the control switch on the control box to the "ICE" position, then move the power
switch to the "ON" position.
4) Replace the front panel in its correct position.
5) Turn on the power supply to start the automatic icemaking process.
6) Once the unit starts to produce ice, allow it to run for another 30 minutes.
7) Turn off the power supply, then remove the front panel.
8) Move the control switch to the "DRAIN" position, then replace the front panel in its
correct position. Turn on the power supply and allow the water system to drain for
5 minutes.
9) Confirm bin control operation:
a) Turn off the power supply, then remove
the front and top panels.
b) Move the power switch to the "OFF"
position.
c) Remove the strap connecting the spout
to the chute assembly. See Fig. 18. Pull
up the chute assembly slightly so that
you can access the actuator located in
the top of the chute.
d) Move the control switch to the "ICE"
position, then move the power switch to
the "ON" position.
WARNING
NOTICE
Strap
Spout
Evaporator Assembly
36
Bin Control
Proximity
Assembly
Switch
Actuator
Fig. 18