3.3 Select options

Press the PRGM and RUN buttons simultaneously.
You will be prompted to answer 8 "Options"
questions, shown below.
As each option is presented:
Use the
buttons to answer each question.
Use HOLD button to advance to the next question
and the TIME button to return
to the previous question.
Options
Default Setting Additional Information
1. Set the temporary
0:00
Hold Time (HOLD)
2. Do you want the
FA
Cycle Rate to be
(fast)
Fast or Slow?
3. Do you want the
ON
display light on
(d-L) for a short
time after any key
is pressed?
Previous
Next
Select desired time, in
15-minute increments, for
the duration of a temporary
override of the current
temperature. If you are not
sure what to chose,
2 hour
setting is usually a good
starting point.
Select SL (slow) if you have
Hydronic (water or steam)
heating. Otherwise, select
default FA.
Use default ON to
enable backlight
14
Options
Default Setting Additional Information
4. Do you want
ON
the Energy
(enabled)
Management
Recovery (E)
function to be
enabled?
5. Do you want
000
to be reminded
(no reminder)
when it is time to
change the
air fi lter? (FLTR)
6. Compressor
OFF
Lockout (LOC)
7. How much
0HI (no offset)
displayed
temperature offset
do you want?
8. Do you want
°F
temperature
(Fahrenheit)
displayed in °C
(Celsius) or °F
(Fahrenheit)?
When you have answered all 8 questions, press the RUN button.
Select default ON.
Ensures the desired
temperature is reached by
the designated program
schedule time
Select default 000 for now.
To set a fi lter-change
reminder, see section 4.4
Select ON to provide
protection to your Heating
and Cooling System's
compressor
Select default 0HI for now.
To adjust the actual
temperature reading, see
section 4.6