Advertisement

4.3 Bypass the schedule
(permanent hold)
You can manually override the currently-programmed temperature
indefi nitely.
1. Use the
buttons to raise or lower the desired temperature.
2. When the desired temperature is displayed, press the HOLD button.
"HOLD" will be displayed at the bottom of the screen.
3. The override
will last until you cancel it.
Cancel the override by pressing the RUN button.
20
4.4 Set change fi lter reminder
The thermostat can display a reminder when it is time to change the air
fi lter on your heating and cooling system.
To enable Change Filter reminder:
1. Press the PRGM and RUN buttons simultaneously.
2. Press the HOLD button four (4) times until you see FLTR in
the display.
3. Using the
buttons select the number of
to be reminded of the fi lter change. The hours increase in
increments of 50.
4. Press RUN when you are fi nished.
5. Once the set time has elapsed, FLTR will be displayed on the screen.
6. Reset the reminder by pressing the HOLD and RUN buttons
simultaneously.
hours
until you would like
21