Storing a Code

1. Press all 4 keys simultaneously and move central selector from OFF
to the desired measuring mode.
The display shows "C _ _ _".
2. Now enter the CODE-number. Any three-digit number can be en-
tered.
Once a CODE has been entered, all subsequently programmed values
can only be changed after entering the CODE number.Once a
"CODE" has been entered, it cannot be erased or changed unless it is
known. If an unknown "CODE" has been programmed, it can only be
read or erased by its author or manufacturer. Therefore note down
your personal "CODE" here.
CODE . . .
3. Inputing the code is done by means of the "CHANGE ITEM" and
"SELECT" keys.
4. Pressing the "DISPLAY MENU" key completes input.
The CODE is now stored, and the display shows "C ON ".
5. If the display "C ON" is acknowledged by pressing "DISPLAY
MENU", the first parameter of the selected measuring function is dis-
played and can be changed with the"CHANGE ITEM" and "SELECT
" keys.
0.000
... 29.99
On/Off
0.000
... 9,99 k
On/Off
Note
Earth/Ground Tester
Procedure of Measurements
0.000
Off
9.99 k
Off
53