Page 23
must be must not exceed must be must be DO NOT...
Page 25
ID-120 (Gas and Steam Only) ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER) IMPORTANT: 208 VAC AND 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage. NOTES: When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed appliance amp draw data.
Page 28
Manifold Pressure* 3.5 inches W.C. In-Line Pressure 6.0 - 12.0 inches W.C. Shaded areas are stated in metric equivalents kcal/hr MODEL Per Hour Rating NUMBER Rating IDG-120 415,000 104,580 Shaded area is stated in metric equivalent TYPE OF GAS NATURAL 8.7 mb 14.92 - 29.9 mb TYPE OF GAS...
Page 31
OPERATING STEAM PRESSURE MAXIMUM MINIMUM HEAT INPUT (NORMAL LOAD) CONSUMPTION (APPROXIMATE) Shaded areas are stated in metric equivalents Minimum operating pressure for optimum results. 125 psig 862 kPa 100 psig* 689 kPa 13 Bhp 450 lbs/hr 204 kg/hr...
Page 33
COM PRESSED AIR SUPPLY Normal Minimum Supply Maximum Supply Shaded areas are stated in metric equivalents AIR PRESSURE 80 PSI 5.51 bars 70 PSI 4.82 bars 90 PSI 6.21 bars...
Page 35
COM PRESSED AIR SUPPLY Normal Minimum Supply Maximum Supply Shaded areas are stated in metric equivalents AIR PRESSURE 80 PSI 5.51 bars 70 PSI 4.82 bars 90 PSI 6.21 bars...
SECTION VII TIM ING LEGEND SPIN TIME Adjustment Position Number Time in Seconds* DWELL (STOP) TIME Adjustment Position Number Time in Seconds* * Values shown are +/- 1-second. 10.2...
Page 52
SECTION X I M P O R T A N T MANUAL RESET HI-LIMIT INSTRUCTIONS FOR PHASE 7 MODELS...
Page 53
This dryer is equipped with a burner hi-limit and tumbler/lint chamber hi-limit thermostat which must be reset manually. Discontinue power to dryer before attempting to reset hi-limit. ADC P/N:114093...