Dome light control (optional)

security only
The dome light activates for 30 seconds after the system is
disarmed.
Ignition controlled
The dome light activates for 30 seconds after the ignition is
turned Off.
door controlled
The dome light activates for 30 seconds after the system sees a
door has closed. (If door was held open for longer than 3
minutes the dome light will not illuminate.)
full
The dome light activates for 30 seconds after seeing door closure,
ignition, or security disarm. (This is the factory setting.)

Silent mode

To temporarily turn off the arm or disarm chirps, use Silent
Mode™. Press
disarming, and the confirmation chirp(s) will be eliminated for
that one operation only. If you want the arm/disarm chirps
turned off permanently, your dealer can do this for you.
note: The Warn Away
bypassed if the system is armed using Silent Mode. This
ensures that no chirps will be emitted by the siren in an
area you want chirp-free. The system is still fully capable
of triggering. Only the Warn Away
22
for less than one second before arming or
response to lighter impacts is
®
®
response is bypassed.