2. Connect three snakes to the MDR24/96 Outputs (top connector). Connect
the plug end of the snakes to the like-numbered Tape Return jacks on the
24•8 console.
1. Set the Sample Clock to Internal.
2. Set the Sample Rate and Bit Depth according to your preference.
Set the 24•8 console to the nominal +4 dBu operating level by setting the
five Operating Level switches in the Sub Out and Tape Return sections to
the 'OUT' position.
AIO•8 Cards
ANALOG I/O ANALOG I/O ANALOG I/O
TAPE IN/OUTS
(3) AIO•8 cards for MDR24/96
(3) AIO•8 cards for D8B
(6) DB25 to DB25 analog snakes
1. Connect three snakes between the MDR24/96 Inputs (bottom connector)
and the corresponding D8B Tape Outputs (top connector).
2. Connect three snakes between the MDR24/96 Outputs (top connector)
and the corresponding D8B Tape Inputs (bottom connector).
1. Set the Sample Clock to Internal.
2. Set the Sample Rate and Bit Depth according to your preference. It is not
necessary to set the D8B and MDR24/96 to the same sample rate since,
with analog connections, the sample clocks on the two units are not
synchronized.
1. Set the D8B Sample Clock to 44.1 k Internal or 48 k Internal according
to your preference.