Performance Data @ AHRI Standard Conditions—Cooling
Model Numbers
Outdoor
Unit
16AJL-
ID Coil
Rev.
5/8/2012
RCFL-H*3824
RCFL-H*3824+RXMD-C04
36
RCFN-H*3624
➀ Highest sales volume tested combination required by D.O.E. test procedures.
[ ] Designates Metric Conversions
Stage
ID Air Mover
1
ROCA-070E03
2
1
ROCA-070E04
2
1
ROLA-070E03
2
1
ROLA-070E04
2
1
ROLA-115E05
2
1
Coil Only
2
1
RGFE-09?ZCM?
2
1
RGFG-09?ZCM?
2
1
RGFG-10?ZCM?
2
1
RGGE-10?ZCM?
2
1
RGGE-12?RCM?
2
1
RGJF-10?ZCM?
2
1
RGJF-12?RCM?
2
1
RGLE-10?BRM?
2
1
RGPE-12?ARM?
2
1
RGRM-07?YBG?
2
1
RGRM-10?ZAJ?
2
1
RGTM-07?RBG?
2
1
ROCA-070E03
2
1
ROCA-070E04
2
1
ROLA-070E03
2
1
ROLA-070E04
2
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Net
Sensible
Latent
Total Capacity
BTU/H [kW]
BTU/H [kW]
BTU/H [kW]
19300 [5.7]
9100 [2.7]
34800 [10.2]
23700 [6.9]
11100 [3.3]
19300 [5.7]
9100 [2.7]
34800 [10.2]
23700 [6.9]
11100 [3.3]
20100 [5.9]
8900 [2.6]
35800 [10.5]
25400 [7.4]
10400 [3.0]
20100 [5.9]
8900 [2.6]
35800 [10.5]
25400 [7.4]
10400 [3.0]
20100 [5.9]
8900 [2.6]
36000 [10.5]
25700 [7.5]
10300 [3.0]
18700 [5.5]
9100 [2.7]
34600 [10.1]
23700 [6.9]
10900 [3.2]
22200 [6.5]
8400 [2.5]
38500 [11.3]
29000 [8.5]
9500 [2.8]
22200 [6.5]
8400 [2.5]
38500 [11.3]
29000 [8.5]
9500 [2.8]
22300 [6.5]
8300 [2.4]
38500 [11.3]
29000 [8.5]
9500 [2.8]
22200 [6.5]
8400 [2.5]
38500 [11.3]
29000 [8.5]
9500 [2.8]
22200 [6.5]
8400 [2.5]
38500 [11.3]
29000 [8.5]
9500 [2.8]
22200 [6.5]
8400 [2.5]
38500 [11.3]
29000 [8.5]
9500 [2.8]
22200 [6.5]
8400 [2.5]
38500 [11.3]
29000 [8.5]
9500 [2.8]
22200 [6.5]
8400 [2.5]
38500 [11.3]
29000 [8.5]
9500 [2.8]
22200 [6.5]
8400 [2.5]
38500 [11.3]
29000 [8.5]
9500 [2.8]
21700 [6.4]
8500 [2.5]
37800 [11.1]
28300 [8.3]
9500 [2.8]
22000 [6.4]
8400 [2.5]
38000 [11.1]
28300 [8.3]
9700 [2.8]
21400 [6.3]
8600 [2.5]
37800 [11.1]
27600 [8.1]
10200 [3.0]
23200 [6.8]
8000 [2.3]
38500 [11.3]
29000 [8.5]
9500 [2.8]
23200 [6.8]
8000 [2.3]
38500 [11.3]
29000 [8.5]
9500 [2.8]
22300 [6.5]
8300 [2.4]
38500 [11.3]
28900 [8.5]
9600 [2.8]
22300 [6.5]
8300 [2.4]
38500 [11.3]
28900 [8.5]
9600 [2.8]
Performance Data
Air
16AJL Series
AHRI Ratings
Indoor
Airflow
SEER
EER
CFM [L/s]
800 [378]
16
12.5
1000 [472]
800 [378]
16
12.5
1000 [472]
900 [425]
15.5
12.5
1175 [554]
900 [425]
15.5
12.5
1175 [554]
900 [425]
16
12.5
1200 [566]
800 [378]
14
11.5
1050 [495]
875 [413]
16
13
1200 [566]
875 [413]
16
13
1200 [566]
900 [425]
16
13
1200 [566]
875 [413]
16
13
1200 [566]
875 [413]
16
13
1200 [566]
875 [413]
16
13
1200 [566]
875 [413]
16
13
1200 [566]
875 [413]
16
13
1200 [566]
875 [413]
16
13
1200 [566]
850 [401]
15
12
1200 [566]
875 [413]
16
13
1150 [543]
800 [378]
16
13
1050 [495]
1000 [472]
16
13
1200 [566]
1000 [472]
16
13
1200 [566]
900 [425]
16
13
1175 [554]
900 [425]
16
13
1175 [554]
Sound
Rating
dB
0
77
0
77
0
77
0
77
0
77
0
77
0
77
0
77
0
77
0
77
0
77
0
77
0
77
0
77
0
77
0
77
0
77
0
77
0
77
0
77
0
77
0
77

Advertisement