Vertical Upflow Dimensional Data
Vertical
Overall Cabinet
Upflow
Model
A
B
C
Width Depth Height
in.
19.1
19.1
22.0
009-012
cm.
48.5
48.5
55.9
in.
21.5
21.5
39.0
018
cm.
54.6
54.6
99.1
in.
21.5
21.5
39.0
024-030
cm.
54.6
54.6
99.1
in.
21.5
26.0
44.0
036 & 042
cm.
54.6
66.0
111.8
in.
24.0
32.5
46.0
048-060
cm.
61.0
82.6
116.8
Condensate is 3/4" IPT
Filter bracket extending from unit 2.5" [6.4 cm]. This bracket should be removed when connecting return duct.
Discharge flange field installed
P
Release
Added GC006-012
Fixed water connection on 018
O
Q
Air Coil & Front Side
Top View-Front Return
P
O
Q
Air Coil Side
Top View-Right Return
S
R
U
T
C
CSP
Front
Right Return Right View
- Air Coil Opening
6
Water Connections
1
2
3
D
E
F
G
H
I
In
Out
Condensate
1.4
2.8
9.4
2.8
6.1
2.3
3.6
7.1
24.0
7.1
15.6
5.9
1.8
3.8
15.2
3.6
8.1
2.3
4.5
9.7
38.6
9.1
20.6
5.8
1.8
3.8
15.2
3.6
8.1
2.3
4.5
9.7
38.6
9.1
20.6
5.8
2.0
3.7
16.2
2.6
10.4
2.3
5.1
9.4
41.1
6.6
26.4
5.8
1.8
5.9
16.7
2.3
10.1
2.3
4.5 14.9 42.4
5.8
25.7
5.8
Notes:
1. Front & Side access is preferred for service access.
. While clear access to all removable panels is not required,
N
installer should take care to comply with all building codes and
allow adequate clearance for future field service.
CAP=Control Access Panel
CSP=Compressor Service Panel
BSP=Blower Service Panel
ASP=Alternate Service Panel
N
P
N
Air Coil Side
Top View-Left Return
U
Air Coil
T
C
CSP
Back
Back
Left Return Left View
- Air Coil Opening
Electrical Knockouts
J
K
L
Water
1/2" cond 1/2" cond 3/4" cond
IPT
Size
Low
Low
Power
Voltage
Voltage
Supply
2.9
5.9
8.9
1/2"
7.3
14.9
22.5
4.1
7.1
10.1
1/2"
10.5
18.1
25.7
4.1
7.1
10.1
3/4"
10.5
18.1
25.7
4.1
7.1
10.1
3/4"
10.5
18.1
25.7
4.1
7.1
10.1
1"
10.5
18.1
25.7
5/13/02
RRB
Standard Filter Bracket
8/25/03
RRB
9/5/03
RRB
Legend
Air Coil
B
O
A
M
S
R
Air Coil
Power Supply
3/4" [19.1 mm] HV
Knockout
Low Voltage
1/2" [12.7 mm] LV
Knockout
Low Voltage
1/2" [12.7 mm] LV
Knockout
Front
* Note: Shaded areas are recommended service areas, not required.
Discharge Connection
Return Connection
duct flange installed (±0.10 in, ±2.54mm)
using return air opening
M
N
O
P
Q
R
Supply
Supply
Width
Depth
8.9
5.1
9.0
9.0
5.5
2.1
22.7 12.9
22.9
22.9
14.0
5.3
6.4
3.8
14.0
14.0
5.3
2.3
16.1
9.5
35.6
35.6
13.6
5.8
6.4
3.8
14.0
14.0
5.3
2.3
16.1
9.5
35.6
35.6
13.6
5.8
6.4
3.8
14.0
14.0
5.1
2.3
16.1
9.5
35.6
35.6
13.1
5.8
6.9
7.3
16.0
18.0
5.1
2.3
17.4 18.4
40.6
45.7
13.1
5.8
Field Installed
Access Panels
Discharge Flange
BSP
ASP
CSP
CAP
Isometric
2' [61cm]
Service
View
BSP
G
2
CAP
3
L
K
CSP
J
1
E
Front-View
S
T
U
Return
Return
Depth
Height
16.2
9.9
0.7
41.1
25.1
1.9
18.3
20.2
0.7
46.5
51.3
1.9
18.3
20.2
0.7
46.5
51.3
1.9
22.8
24.2
0.7
57.9
61.4
1.9
29.3
24.2
0.7
74.4
61.4
1.9
2' [61cm]
Service
Access *
Left Rtn
(Right Rtn
Opposite
Side)
1.00 [25.4 mm]
Condensate
3/4" IPT
F
I
H
D