Download Print this page

GE JBS03 Owner's Manual And Installation Ins page 39

Coil top and radiant top models

Advertisement

mnstaliation
mnstructions
@
[]
3°WIRE CONDUIT iNSTALLATiON
Loosen
the 3 lower terminal
screws
from
the terminal
block. Insert the center bare
wire
(wMte/neutrat)
tip through
the bottom
center terminat
block opening.
On certain
models,
the wire will need to be inserted
through
the ground
strap opening
and then
into the bottom
center block opening.
Insert
the two side bare wire tips into the lower
left and the lower
right terminal
block
openings.
Tighten
the screws
until the wire
is firmly
secure (approximately
20 inchqbs.).
NOTE:
ALUMINUM
WmRING:
Aluminum
building
wire
may be used
but it must
be rated for the correct
amperage
and voltage
to make
connection.
Connect
wires
according
to this Step 6 or Step 7 depending
on
number
of wires.
Terminal
t__
_
_
wiretips
i
Conduit
Wire
used, location
and enclosure
of sptices,
etc., must
conform
to good
wiring
practices
and local
codes.
[]
Skip to Step 8 and proceed
with the
installation.
4-WIRE CONDUIT INSTALLATION
[]
[]
Loosen the three lower terminal
screws
from the terminal
block. Remove
the ground
screw and ground
plate and retain them.
Cut and discard the ground
strap. DO NOT
DISCARD ANY SCREWS.
Insert the ground
bare wire tip between the
range frame and the ground
plate (removed
earlier) and secure it in place with the ground
screw (removed
earlier),
Insert the bare wire
(white/neutral)
tip through
the bottom
center
of the terminal
block opening.
Insert the two
side bare wire tips into the lower left and the
lower right terminal
block openings.
Tighten
the screws until the wire is firmly
secure
(approximately
20 inch-lbs.).
Ground
screw
und strap
k__or
_
eutral
minal
Ground
plate
(grounding
to range)
\
Bracket
Wire
used, location
and enclosure
of splices, etc., must
conform
to good
wiring
practices
and local codes.
[]
Proceed to Step 8.