INSTALLATIONINSTRUCTIONS
CONNECTING ELECTRIC DRYERS
(cont.)
a, WARNING:
• Connect
the power
cord to the terminal
block.
Each colored
wire should
be connected
to
same color screw. Wire color indicated
on manual
is connected
to the same color screw
in block.
Failure to follow
these
instructions
may result in a short or overload.
• Grounding
through
the neutral
conductor
is prohibited
for: (1) new branch-circuit
installations,
(2) mobile
homes,
(3) recreational
vehicles,
and (4) areas where
local
codes
prohibit
grounding
through
the neutral
conductor.
_
Three-Wire
Connection
for Electric Dryers: Power
Cord
• A 3-wire connection is NOT permitted on new
construction
after January 1, 1996.
• A UL-listed strain relief is required.
Terminal
Block
, UL-Listed
Strain Relief
3-Wire
Remove the terminal block access cover
on the upper back of the dryer. Install a
UL-listed strain relief into the power cord
through-hole;
then thread a UL-listed, 30A,
240V, 3-wire, #10 AWG-minimum
copper
conductor
power cord through the strain
relief.
• Use a 30-amp, 240V, UL-listed power cord
with #10 AWG-minimum
copper conductor
and closed loop or forked terminals with
upturned ends.
,, . --Ne_
(_,°'ack) 0Nhite)
_R_eLd) _
Attach the two hot leads of the power cord
to the outer terminal block screws.
Attach
the neutral wire to the center terminal block
screw. Connect
the external
ground
(if
required
by local codes) to the green ground
screw. TIGHTEN ALL SCREWS SECURELY.
Reinstall the terminal block access cover.