Kenmore 30" ELECTRIC RANGE Installation Instructions page 3

Hide thumbs Also See for 30" ELECTRIC RANGE:

Advertisement

See Range C onnection
Opening Size Chart ( Figs. 9&10) f or
cord kitampere rating information.
Terminals onend ofwires
must b eeither c losed l oop oropen-end spade l ugs withupturned
ends.
2b. MODELS
REQUIRING
POWER
SUPPLY
CORD
KIT.
RISK OF FIRE OR ELECTRICAL
SHOCK
MAY OCCUR
IF AN
INCORRECT
SIZE RANGE
CORD
KIT IS USED,
THE
INSTALLATION
INSTRUCTIONS
ARE NOT FOLLOWED
OR
STRAIN
RELIEF
BRACKET
IS DISCARDED.
This appliance
may be connected
by means
of a power
supply
cord. Only a power
supply
cord kit rated at 125/250
volts
minimum,
and marked
for use with ranges
shall be used. See Fig.
10 for cord kit ampere
rating
information.
Cord must have either
three
(3) or four (4) conductors
(See Fig. 8). Terminals
on end of
wires
must be either
closed
loop or open-end
spade
lugs with
upturned
ends. Cord must have strain
relief properly
installed.
See
Steps 4a. for 4-Wire
or 4b. for 3-Wire
connections.
3. ELECTRICAL
CONNECTION
TO RANGE.
The Rear Access Cover must be removed (Fig 9). To remove,
loosen center screw (one screw) and remove cover. The terminal
block will then be accessible.
Separate
Strain Relief
before installation
Fig, 11
4A. POWER
CORD
CONNECTIONS
(4-Wire Connection
Instructions
- Refer to Fig.12)
Before wiring the range review the suggested power source
location drawing in Fig. 3. If connecting to a 4-Wire electrical
system (new branch-circuit
or mobile home requires 4-Wire
connection):
3 & 4 -Wire electrical
wall Receptacle types &
Fig, 8
Required for new and
remodeled installations
4 Wire Wall
Receptacle (14-50R)
O
Allowed for
exisiting installations
3 Wire Wall
Receptacle (t 0-50R)
NOTE:
Range
is shipped
from factory
with 1-3/8" dia. hole as
shown.
To use either
7/8" dia. hole or 1-1/8" dia. knockouts
refer
to Fig. 9.
1-1/8"
Dia.
7/8" Dia.
';_;:
Knockout
Hole
_ear
(See Chart)
(See Chart)
_ess
_ver
Mounting
I
Plate
Fig, 9
1-3/8"
Pocket
Hole
for Cable
(See Chart)
Mounting
Plate
Range
Connection
Opening
Size Chart
Supply Cord Kit ampere rating information.
See serial plate on range
for kilowatt
rating
data.
See Serial Plate on Range for
KW Rating
120/240 Volts 120/208 Volts
Cord Kit
Ampere
Rating
8.8-16.5
KW
7.9-12.5
KW
40/50 Amp
16.6-22.5
KW
12.6-18.5
KW
50Amp
Fig.
10
Diameter
(inches)
of Range
connection
Opening
Permanent
Cord Kit
Wiring
1-3/8 in,
1-1/8 in,
1-3/8
in.
1-3/8 in.
1.
Follow
the manufacturer's
installation
instructions
supplied
with the strain relief and install
(Also see Figs. 9, 10 & 11).
2.
insert the end connectors
for Line 1, Line 2 and Neutral
and
tighten
securely
to the terminal
block.
IMPORTANT
NOTE:
DO NOT LOOSEN
the factory
installed
nut connections
which
secure
the range wiring to the
terminal
block.
Electrical
failure
or loss of electrical
connection
may occur
if these
3 nuts are loosened
or
removed.
3.
You must disconnect
the ground
strap.
Remove
the
factory
installed
ground
screw
& plate to release
the copper
ground
strap from the frame
of the appliance.
Cut and
discard
the copper
ground
strap & plate. KEEP the ground
screw.
4.
Connect
the ground
wire (Green)
lead with the eyelet to the
frame of the appliance
with the ground
screw
using the same
hole in the frame
where the ground
screw
was originally
installed
(See Fig. 12).
5.
Make sure all screws
are tightened
securely
and replace
the
rear access
cover
(See Fig. 9).
4-Wire
Connection
Factory installed connections (DO NOT LOOSEN)
Terminal
Connect
Line 1
Connect
here
2
Connect
here
Neutral
(White or
Center)
Cut Ground
Strap. Discard
Ground Strap
& Ground Plate
Connect
Green
insulated
Copper
Ground
Wire with
Ground
Screw here
NOTES:
Install Strain-Relief
Bushing, Center or white
wire must always be
Fig.
12
attached to the center
terminal on block