3. Secure the cable by fastening the clamp screw.
4. Close the cover of the terminal board.
Electrical Connection:
Voltage Frequency: see data plate
Fuse Section: 16A
Supply cable: 3x1.5mm
You can connect your oven to the system means of a
terminal board. Refer to above information for the minimal
cable sections and the calibration of the protective elements
according to the connection.
If the appliance is installed with a junction box, an
omnipolar circuit breaker - with a minimum contact
opening of 3mm - should be installed between the appliance
and the mains.
Power cable supply connection to the electrical mains:
We recommend you use a power supply cable which is
long enough to allow you to take the oven out of its recess
in the event of maintenance operations (only use HAR - H
05 - RRF quality cables fitted with a plug conforming to the
regulations in force.
The plug must be accessible at all times.
Unplug the appliance before all operations, even when
replacing the oven lamp.
Using the appliance without correct earthing is highly
dangerous.
! After connecting the appliance to the flexible cable,
tighten all the screws on the terminal board.
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
2
APPLIANCE SPECIFICATIONS
width 43.5 cm
Dimensions*
height 32,4 cm
depth 41.5 cm
Volume*
59 l
width 45.5 cm
Dimensions**
height 32,4 cm
depth 41.5 cm
Volume**
62 l
voltage: 230-240V~ 50/60Hz or 50Hz
Electrical
(see data plate)
connections
maximum power absorbed
2800-3000 W
Directive 2002/40/EC on the label
of electric ovens. Standard EN 50304
ENERGY
Declared energy consumption
LAB EL
for Forced convection Class –
heating mode:
ECO.
* Only for models with drawn rails.
** Only for models with wire rails.