• Check if the remote controller display shows
"
" (time to clean the air filter);
Refer to the operation manual of the indoor unit.
And clean the air filter.
• Check the temperature setting.
Refer to "Operation procedure".
• Check the fan speed setting on your remote con-
troller.
Refer to "Operation procedure".
• Check for open doors or windows.
Shut doors and windows to prevent wind from
coming in.
• Check if there are too many occupants in the
room during cooling operation.
• Check if the heat source of the room is excessive
during cooling operation.
• Check if direct sunlight enters the room during
cooling operation.
Use curtains or blinds.
• Check if the air flow angle is not proper.
Refer to "Operation procedure".
After-sales service and warranty
After-sales service:
DANGER

• Refrigerant gas may produce a toxic gas if it

comes in contact with fire such as from a fan,

heater, stove or cooking device. Exposure to

this gas could cause severe injury or death.

WARNING
• Do not disassemble, modify or repair the unit.
This may cause water leakage, electric shock or fire.
Contact your dealer.
• Do not remove or reinstall the unit by yourself.
Incorrect installation may cause water leakage,
electrical shock or fire.
Contact your dealer.
• When asking your dealer to repair, inform
related staff of the details as follows:
• Model name and product No. of air conditioner:
Refer to the warranty card.
• Shipping date and installation date:
Refer to the warranty card.
• Malfunction:
Inform the staff of the defective details.
(Malfunction code being displayed on
the remote controller.)
• Name, address, telephone number
15
• Repair after the warranty term is expired
Contact your dealer. If necessary to repair, pay
service is available.
• Minimum storage period of important parts
Even after a certain type of air conditioner is dis-
continued, we have the related important parts in
stock for 9 years at least.
The important parts indicate parts essential to
operate the air conditioner.
• Recommendations for maintenance and
inspection
Since dust collects after using the unit for several
years, the performance will be deteriorated to
some extent.
Disassembling and cleaning inside require techni-
cal expertise, so we recommend entering a main-
tenance and inspection contract (at a cost)
separate from normal maintenance.
• Recommended inspection and maintenance
cycles
[Note: The maintenance cycle is not the same
as the warranty period.]
Table 1 assumes the following usage conditions.
1. Normal use without frequent starting and stop-
ping of the machine.
(Although it varies with the model, we recom-
mend not starting and stopping the machine
more than 6 times/hour for normal use.)
2. Operation of the product is assumed to be
10 hours/day, 2500 hours/year.
• Table 1 "Inspection Cycle" and "Maintenance
Cycle" Lists
Name of Main Part
Compressor
Electric motor (fan, damper, etc.)
PC boards
Heat exchanger
Sensor (thermistor, etc.)
Remote controller and switches
Drain pan
Expansion valve
Electromagnetic valve
FAN

Note 1

This table indicates main parts.
See the maintenance and inspection contract for
details.
Maintenance Cycle
Inspection
[replacements and/or
Cycle
repairs]
20,000 hours
20,000 hours
25,000 hours
5 years
5 years
1 year
25,000 hours
8 years
20,000 hours
20,000 hours
Outside : 10 years
Indoor : 13 years
English