PERFORMANCE
DATA SHEET
Water Filtration System
Model
P5WB12NL/P4RFWB12
Capacity
120 Gallons
(455 Liters)
System
tested and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of Chlorine
Taste and Odor, and Particulate
Class I*; and against
NSF/ANSI
Standard
53 for the reduction
of Live
Cysts, Asbestos,
Lead, Lindane, Toxaphene,
Atrazine,
and 2,4 - D.
This system
has been tested
according
to NSF/ANSI
Standards
42 and 53 for the reduction
of the substances
listed below. The
concentration
of the indicated
substances
in water entering
the system was reduced
to a concentration
less than or equal to the
permissible
limit for water leaving the system,
as specified
in NSF/ANSI
Standards
42 and 53.
Substance
Reduction
Aesthetic
Effects
Chlorine Taste/Odor
Particulate Class I*
Contaminant
Reduction
Live Cysts t
Asbestos
Lead: @ pH 6.5
Lead: @ pH 8.5
Lindane
Toxaphene
Atrazine
2,4 - D
NSF Reduction
Requirements
50% reduction
85% reduction
NSF Reduction
Requirements
99.95%
99%
0.010 mg/L
0.010 mg/L
0.0002 mg/L
0.003 mg/L
0.003 mg/L
0.07 mg/L
Average
Influent
2.0 mg/L
7,300,000 #/mL
Average
Influent
160,000/L
87 MFL
0.160 mg/L
0.140 mg/L
0.0019 mg/L
0.014 mg/L
0.0094 mg/L
0.220 mg/L
Influent Challenge
Concentration
2.0 mg/L _+10%
At least 10,000 particles/mL
Influent
Challenge
Concentration
50,000/L rain.
107to 108fibers/U _
0.15 mg/L _+10%
0.15 rag/L_+ 10%
0.002 mg/L _+10%
0.015 mg/L _+10%
0.009 rag/L_+ 10%
0.210 rag/L_+ 10%
Maximum
Effluent
0.20 mg/L
75,000 #/mL**
Maximum
Effluent
54/U
0.17 MFL
0.001 mg/L
0.005 mg/L
0.00002 mg/L
0.001 mg/L
0.0005 mg/L
0.028 mg/L
Minimum %
Reduction
97
99
Minimum %
Reduction
99.97
99
99.4
98.6
98.9
93
94.5
87.5
Test Parameters:
pH = 7.5 + 0.5 unless otherwise
noted.
Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service
capacity
= 120 gallons
(455 liters).
It is important
that operational,
maintenance,
and filter
replacement
requirements
be carried
out for the product
to
perform
as advertised.
Property
damage
can occur if all
instructions
are not followed.
Use replacement
filter P4RRWB/P4RFWB12,
part #W10295370.
2012 suggested
retail price of $49.99
U.S.A./S59.99
Canada.
Prices are subject
to change
without
notice.
Style
1 - When the water filter status
display
changes
from
"GOOD"
to "ORDER,"
order
a new filter. When the filter
indicator
reads
"REPLACE,"
it is recommended
that you
replace
the filter.
Style 2 - When the filter indicator changes from green to
yellow, order a new filter. When the indicator changes from
yellow to red, it is recommended
that you replace the filter.
Style 3 - When the filter indicator reads 10%, order a new
filter. When the indicator reads 0%, it is recommended
that
you replace the filter.
Average
%
Reduction
97.2
99.4
Average
%
Reduction
99.99
99
99.4
98.6
99
93
94.7
96.1
The product
is for cold water use only.
The water system must be installed
in compliance
with state and
local laws and regulations.
Do not use with water that is microbiologically
unsafe or of
unknown
quality without
adequate
disinfection
before or after the
system.
Systems
certified
for cyst reduction
may be used on
disinfected
waters that may contain
filterable
cysts.
Refer to the "Warranty"
section
for the Manufacturer's
name,
address
and telephone
number.
Refer to the "Warranty"
section
for the Manufacturer's
limited
warranty.
Application
Guidelines/Water
Supply Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service
Flow Rate
0.5 gpm
(1.9 Lpm) @ 60 psi
Style 4 - For models without a water dispenser, replace the
disposable water filter every 6 months. The water filter
indicator light will remind you when it is time to change the
water filter.
After changing
the water filter, flush the water system.
For filtered
ice only, make and discard
three full containers
of ice to prepare
the water filter for use.
These contaminants
are not necessarily
in your water supply.
While testing
was performed
under standard
laboratory
conditions,
actual performance
may vary.
%
*Class I particle size: >0.5 to <1 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
tBased on the use of Cryptosporidium
parvum oocysts
ttFibers greater than 10 um in length
® NSF is a registered trademark
of NSF International.