Performance Data Sheet - Whirlpool WRF954CIHZ01 Use & Care Manual

French door refrigerator
Table of Contents

Advertisement

This system has been tested according to NSF/ANSI Standards 42, 53, 401, and CSA B483.1 for the reduction of the substances
listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or
equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standa rds 42, 53, 401, and CSA B483.1.
Substance Reduction Aesthetic
Effects
Chlorine Taste/Odor
Particulate Class I*
Contaminant Reduction
Lead: @ pH 6.5 / @ pH 8.5
Benzene
p-Dichlorobenzene
Carbofuran
Toxaphene
Atrazine
Asbestos
Live Cysts†
Turbidity
Lindane
Tetrachloroethylene
O-Dichlorobenzene
Ethylbenzene
1,2,4-Trichlorobenzene
2,4 - D
Styrene
Toluene
Endrin
Atenolol
Trimethoprim
Linuron
Estrone
Nonylphenol
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.75 gpm (2.84 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to
22°C). Rated service capacity = 200 gallons (757 liters).
The compounds certified under NSF 401 have been deemed as "emerging compounds/incidental contaminants." Emerging compounds/incidental
contaminants are those compounds that have been detected in drinking water supplies at trace levels. While occurring at only trace levels, these
compounds can affect the public acceptance/perception of drinking water quality.
It is important that operational, maintenance, and filter replacement
requirements be carried out for the product to perform as advertised.
Property damage can occur if all instructions are not followed.
The disposable cartridge must be changed at least every 6 months.
Use replacement filter P9RFWB2L, part #EDR2RXD1/EDR2RXD1B.
2015 suggested retail price of $49.99 U.S.A./$49.99 Canada. Prices
are subject to change without notice.
The filter monitor system measures the amount of water that passes
through the filter and alerts you when it is time to replace the filter.
Refer to the "Using the Controls" or "Water Filtration System" section
(in the User Instructions or User Guide) to learn how to check the
water filter status.
After changing the water filter, flush the water system. See "Water
and Ice Dispensers" or "Water Dispenser" in the User Instructions or
User Guide.
These contaminants are not necessarily in your water supply. While
testing was performed under standard laboratory conditions, actual
performance may vary.
The product is for cold water use only.
The water system must be installed in compliance with state and
local laws and regulations.
*Class I particle size: >0.5 to <1 um
Based on the use of Cryptosporidium parvum oocysts
Fibers greater than 10 um in length
††
NSF is a registered trademark of NSF International.
®
PERFORMANCE DATA SHEETS
Water Filtration System
Model P9WB2L/P9RFWB2L Capacity 200 Gallons (757 Liters)
System tested and certified by NSF International against NSF/ANSI
Standard 42, Standard 53, Standard 401, and CSA B483.1 for
the reduction of contaminants specified on the Performance
Data Sheet.
Influent Challenge Concentration
2.0 mg/L ± 10%
At least 10,000 particles/mL
Influent Challenge Concentration
0.15 mg/L± 10%
0.015 mg/L ± 10%
0.225 mg/L ± 10%
0.08 mg/L ± 10%
0.015 ± 10%
0.009 mg/L ± 10%
10
to 10
fibers/L††
7
8
50,000/L min.
11 NTU ± 10%
0.002 ± 10%
0.015 mg/L ± 10%
1.8 mg/L ± 10%
2.1 mg/L ± 10%
0.210 mg/L ± 10%
0.210 mg/L ± 10%
2.0 mg/L ± 10%
3.0 mg/L ± 10%
0.006 mg/L ± 10%
200 ± 20%
140 ± 20%
140 ± 20%
140 ± 20%
1400 ± 20%
Maximum Permissable Product
Water Concentration
50% reduction
85% reduction
Maximum Permissable Product
Water Concentration
0.010 mg/L
0.005 mg/L
0.075 mg/L
0.040 mg/L
0.003 mg/L
0.003 mg/L
99%
99.95%
0.5 NTU
0.0002 mg/L
0.005 mg/L
0.60 mg/L
0.70 mg/L
0.07 mg/L
0.07 mg/L
0.1 mg/L
1.0 mg/L
0.002 mg/L
30 ng/L
20 ng/L
20 ng/L
20 ng/L
200 ng/L
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected
waters that may contain filterable cysts.
EPA Est. No. 082047-TWN-001
Refer to the "Warranty" section (in the User Instructions or User
Guide) for the Manufacturer's limited warranty, name, and telephone
number.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Average % Reduction
9 7.0%
>99.9%
Average % Reduction
>99.3%/98.6%
93.8%
99.8%
81.9%
>95%
87.0%
>99%
>99.99%
96.9%
>99.2%
96.6%
92.3%
86.9%
>99.8%
88.5%
99.6%
93.5%
81.7%
95.7%
96.1%
96.3%
95.3%
95.5%
Potable City or Well
35 - 120 psi (241 - 827 kPa)
33° - 100°F (1° - 38°C)
0.75 gpm (2.84 L/min.) @ 60 psi
41

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wrf954cihv00Wrf954cihm00

Table of Contents