Performance Data Sheet - Whirlpool 8WRS21SNHW Health & Safety, Use & Care And Installation Manual

Table of Contents

Advertisement

This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance
NSF Reduction
Reduction
Requirements
Aesthetic Effects
Chlorine Taste/Odor
50% reduction
Particulate Class I*
85% reduction
Contaminant
NSF Reduction
Reduction
Requirements
Live Cysts
99.95%
Asbestos
99%
Lead: @ pH 6.5
0.010 mg/L 0.010
Lead: @ pH 8.5
mg/L
Lindane
0.0002 mg/L
Toxaphene
0.003 mg/L
Atrazine
0.003 mg/L
2,4 - D
0.07 mg/L
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
It is important that operational, maintenance, and filter
replacement requirements be carried out for the product
to perform as advertised. Property damage can occur if all
instructions are not followed.
Use replacement filter according you filtration system, see"Ice
and Water" in the User Guide.
Water Filter:
Water Filtration System Style 1 - Order Part # EDR1RXD1
Water Filtration System Style 2 - Order Part # EDR2RXD1
When the water filter status changes from TURN OFF to
RED light on your control panel, it is recommended that you
replace the filter.
After changing the water filter, flush the water system. See
"Water and Ice Dispensers" or "Water Dispenser" in the User
Instructions or User Guide.
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
Based on the use of Cryptosporidium parvum oocysts
Fibers greater than 10 um in length
††
NSF is a registered trademark of NSF International.
18

PERFORMANCE DATA SHEET

Water Filtration System
Model P5WB2L/P4RFWB Capacity 200 Gallons (757 Liters)
System tested and certified by NSF International against NSF/ANSI
Standard 42 for the reduction of Chlorine Taste and Odor, and Particulate
Class I*; and against NSF/ANSI Standard 53 for the reduction of Live
Cysts, Asbestos, Lead, Lindane, Toxaphene, Atrazine, and 2,4 - D.
Average
Influent
2.0 mg/L
7,300,000 #/mL
Average
Influent
160,000/L
87 MFL
0.160 mg/L 0.140
mg/L
0.0019 mg/L
0.014 mg/L
0.0094 mg/L
0.220 mg/L
Influent Challenge
Maximum
Concentration
Effluent
2.0 mg/L ± 10%
0.20 mg/L
At least 10,000 particles/mL
75,000 #/mL**
Influent Challenge
Maximum
Concentration
Effluent
50,000/L min.
54/L
10
7
to 10
8
fibers/L
††
0.17 MFL
0.15 mg/L ± 10%
0.001 mg/L
0.15 mg/L ± 10%
0.005 mg/L
0.002 mg/L ± 10%
0.00002 mg/L
0.015 mg/L ± 10%
0.001 mg/L
0.009 mg/L ± 10%
0.0005 mg/L
0.210 mg/L ± 10%
0.028 mg/L
The product is for cold water use only.
The water system must be installed in compliance with state
and local laws and regulations.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
Refer to the "Warranty" section (in the User Instructions
or User Guide) for the Manufacturer's name, address and
telephone number.
Refer to the "Warranty" section (in the User Instructions or
User Guide) for the Manufacturer's limited warranty.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Minimum %
Average %
Reduction
Reduction
97
97.2
99
99.4
Minimum %
Average %
Reduction
Reduction
99.97
99.99
99
99
99.4
99.4
98.6
98.6
98.9
99
93
93
94.5
94.7
87.5
96.1
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 gpm (1.9 Lpm) @ 60 psi

Advertisement

Table of Contents
loading

Table of Contents