Download Print this page
Panasonic KS24NKU Manual
Panasonic KS24NKU Manual

Panasonic KS24NKU Manual

Wall mounted air conditioner

Advertisement

Quick Links

Split System Submittal Data
Wall Mounted Air Conditioner
System: KS24NKU Indoor/Outdoor: CS-KS24NKU/CU-KS24NKU
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Power
V/PH/Hz
Circuit Ampacity
Fuse Size, Max.
Compressor
No. used
R.L. Amps - L.R.
Crankcase Heater
Outdoor Unit
Fan type
Dia. (in.) - No. Speeds
Type Drive - No. Speeds
No. Poles
No. Motors
(High)
CFM
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
(sq.ft.)
Face Area
Tube Size
Indoor Unit
Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
(RPM, High)
No. Poles
No. Motors
(HI/Med/Lo)
CFM
Indoor Sound Rating
(Hi) (dB-A)
F.L. Amps
Coil Type
Aluminum Plate Fin & Copper Tube
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
(sq.ft.)
Tube Size
Drain Connection Size
(in.)
General Data (at 230V)
230/208/1/60
(A)
20
(A)
20
DC Rotary Inverter
(A)
9.6/10.9 - 17.5
(W)
Propeller
18 - 1/8 - 1
DC Motor
(RPM)
8 - 850
(W)
(A)
Aluminum Fin & Copper Pipe
Corrugated Plate - Inner Riffl ed
2 - 18.1
(in.)
Cross Flow
3-11/16 33-9/32 - 1
3 & Auto
8 - 1250
(W)
600/541/482
(A)
Slit Plate - Inner Riffl ed
2 - 19.5
(in.)
23/32"
Approval:
Date:
Construction:
Unit #:
Drawing #:
Refrigerant
Lbs. - R410a (outdoor unit)
1
Control
Connection
-
Line Length, Max
Lift Diff erence, Max
Line Size
Line Size
Dimensions
Indoor Unit
90 - 1
600
Outdoor Unit
0.7
Weight
Net
Shipping
6.4
3/8"
Shipping Volume
Performance Data @ ARI Standard Conditions (230V)
Cooling
Total Capacity
Sensible Capacity
30 - 1
Latent Capacity
SEER
Dehumidifi cation
47
0.5
Amps
Power Inputs
Outdoor Sound Rating
3.07
9/32"
Electric Expansion Valve
(in. O.D. Discharge)
(in. O.D. Suction)
(in.)
(Uncrated)
11-23/32 x 41-15/16 x 8-19/32
(Crated)
11-3/8 x 44-7/8 x 14-29/32
(Uncrated)
29-1/8 x 35-7/16 x 12-19/32
(Crated)
33-27/32 x 40-5/8 x 16-1/4
Indoor
(lbs.)
26.5
(lbs.)
33.1
Indoor
(cu.ft.)
4.23
(BTU/H)
24,200 (4,100-24,200)
(BTU/H)
(BTU/H)
(Pints/H)
(A)
10.8/12.1(1.3-12.1)
(W)
2,355/2,355 (280-2,355)
(dB-A)
R410A
4.30
Flare
131
50
1/4"
5/8"
H x W x D
Outdoor
119
127.9
Outdoor
12.71
14,800
9,400
17
4.89
55

Advertisement

loading
Need help?

Need help?

Do you have a question about the KS24NKU and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Panasonic KS24NKU

  • Page 1 Split System Submittal Data Wall Mounted Air Conditioner System: KS24NKU Indoor/Outdoor: CS-KS24NKU/CU-KS24NKU Job Name: Approval: Location: Date: Engineer: Construction: Submitted to: Unit #: Submitted by: Drawing #: Reference: General Data (at 230V) Power V/PH/Hz 230/208/1/60 Circuit Ampacity Fuse Size, Max.
  • Page 2 Dimensions Feature Option Available Controls Refrigerant Line Set Microprocessor Remote Controller Fresh Air Intake LCD Wireless Type, Temp. Sensor Built In Temperature Control Airduct Extension IC Thermostat Timer Indoor Frame Extension 24 Hr. Program, 1 Hr. Off Night Setback Condensate Drain Pump Available Built-In Air Louver...

This manual is also suitable for:

Cs-ks24nkuCu-ks24nku