Safety distances underneath the hob
To ensure sufficient ventilation to the
hob, a minimum gap must be left
between the underside of the hob and
any oven, interim shelf or drawer.
The minimum gap between the
underside of the hob and
– the top of an oven is 15 mm.
– the top of an interim shelf is 15 mm.
– the base of a drawer must be
75 mm.
Safety instructions for installation
Interim shelf
It is not necessary to fit an interim shelf
underneath the hob, but one may be
fitted if you wish.
A ventilation gap of 10 mm at the back
of the hob is necessary to
accommodate the cabling.
We recommend a ventilation gap at the
front of the hob of 20 mm to ensure
good ventilation.