Exhaust Duct - KitchenAid KHMS 105 Installation Instructions Manual

30” built-in microwave/hood / microwave-convection hood
Table of Contents

Advertisement

HOOD
EXHAUST DUCT
Outside
ventilation
requires
HOOD
EXHAUST
DUCT.
Read the following
carefully.
EXHAUST
CONNECTION:
The hood
exhaust
has been
designed
to mate
with
a standard
3-x"
x 10" rectangular
duct.
If round
duct
is required,
a rectangular-to-round
transition
adaptor
must be used. DO not use
less than a 6" diameter
duct.
REAR EXHAUST:
If rear or horizontal
exhaust
is to be used, care should
be taken
to align ex-
haust with space between
studs, or wall should
be prepared
at the time it is constructed
by leav-
ing enough
space between
wall studs to accommodate
exhaust.
MAXIMUM
DUCT LENGTH:
For satisfactory
air movement,
the total duct length.of
3-x"
x 10"
rectangular
or 6" diameter
round
duct should
not exceed
140 feet.
ELBOWS,
TRANSITIONS,
WALL and ROOF CAPS, etc. present
additional
resistance
to air flow and are
equivalent
to a section
of straight
duct which
is longer
than their actual
physical
size. When calculating
the total
duct
length
add the equivalent
lengths
of all transitions
and adaptors
plus the lengths
of all
straight
duct
sections.
The diagram
below
shows the approximate
feet of equivalent
length
of some
typical
ducts.
EXHAUST
DUCT
@a
90° ELBOW
10 FT.
10" WIDE ELBOW
10 FT.
WALL CAP
40 FT.
45O ELBOW
TRANSITION
ADAPTOR
5 FT.
5 FT.
90' ELBOW
I
4.5O ELBOW
I
25 FT.
5 FT.
1
I
ROOF CAP
24 FT.
6