Installation
instructions
Minimum
Clearance Other Than Alcove or Closet Installation
I
Minimum
clearance to combustible
sm'faces and for air opening are: 0 in. clearance both sides and 1 in. rear. Consideration
_or
installation and service.
!
[]
PREPARING
FOR INSTALLATION
[]
ELECTRICAL
CONNECTION
OF NEW DRYER
iNFORMATiON
EXTERNAL
DUCT
OPENING
OR
DUCT CLAMP
DUCTTAPEOR
DUCTCLAMP
4"METALDUCT
TIP: Install your dryer before installing
your washer.
This will allow better access when installing
dryer exhaust.
REMOVING
LiNT FROM
WALL
EXHAUST
OPENING
WALL
CHECKTHATEXHAUST
tHOODDAMPEROPENS
ANDCLOSESFREELY.
TILTTHEDRYER SIDEWAYS
AND REMOVE THE FOAM
SHIPPING PADSBY
PULLINGATTHE SIDES
AND BREAKING THEM
AWAYFROM THE DRYER
LEGS,BESURE TO
REMOVEALLOFTHE
FOAM PIECES AROUND
THELEGS.
INTERNALDUCT
OPENING...._
WARNING
- TO REDUCE
THE RISK
OF
FIRE_ ELECTRICAL
SHOCK
AND
PERSONAL
INJURY:
- DO
NOT
USE
AN EXTENSION
CORD
OR AN
ADAPTER
PLUG
WITH
THIS
APPLIANCE.
Dryer
must be electrically
grounded
in accordance
with
local codes
and ordinances,
or in the absence
of local
codes,
in accordance
with the NATIONAL
ELECTRI-
CAL CODE,
ANSI/NFPA
NO.
70.
ELECTRICAL
REQUIREMENTS
This dryer must be comlected
to an individual
branch circuit,
protected
by the required time-delay fuses or circuit breakers. A
four or three-wire,
single phase, 120/240V
or 120/208V,
60Hz,
30 amp circuit is required.
If the electric supply does not meet the above specifications,
then
call a licensed electrician.
GROUNDING
iNSTRUCTiONS
This dryer must be connected
to a grounded
metal, permanent
wiring system, or an equipment-grounding
conductor
must be run
with the circuit conductors
and connected
to the equipment-
grounding
terminal on the appliance.
CONNECTING
DRYER USING 4-WIRE
CONNECTION
(MUST
BE USED FOR
MOBILE HOME INSTALLATION)
NOTES: Since January 1,1996, the National Electric code requires
that the new constructions utilize a 4-wire connection to
an electric dryer
WARNUNG:Only
a 4-conductor cord shall be used when the
appliance is installed in a location where grounding through the
neutral conductor is prohibited. Grounding through the neutral is
prohibited for the new branch-circuit installations, mobile homes
recreational vehicles, and areas where local codes prohibit
grounding through the neutral conduction.
REMOVE
GROUND
STRAP
AND DISCARD.
KEEP G REEN
HOT _ "_,
GROUNDSCREW
WIRE RELOCATE
GREEN
_'_-...
GROUND S CREW
HERE
GREEN OR
J
3/4",UL
HOT
RECOGNIZED
WIRE
STRAIN RELIEF
4 #10AWGMINIMUM COPPER
COVER
CONDUCTORS OR 120/240V 30A POWER
SUPPLY C ORD KITMARKED FORUSE
WiTHDRYERS & PROVIDED WITH
CLOSED LOOPOR SPADETERMINALS
2
WiTHUPTURNED ENDS (NOTSUPPLIED}.