Download Print this page

GE 31-16222 Installation Manual

Comercial stacked electric dryers

Advertisement

Quick Links

WA
I G -RISK OF RRE
To reduce the risk of severe injury or death, follow' all installation instructions.
Clothes dryer installation must be performed by a qualified installer.
Install the clothes dryer according to these instructions and in accordance with local codes.
This dryer must be exhausted to the outdoors.
Use only 4" rigid metal ducting for exhausting the clothes dryer to the outdoors.
DO NOT install a clothes dryer with flexible plastic ducting materials.
If flexible metal (semi-rigid or foil-type) duct is
installed, it must be UL listed and installed in accordance with these instructions and local codes. Flexible venting
materials are known to collapse, be easily crushed, and trap lint. These conditions will obstruct dryer airflow and
increase the risk of fire.
Do not install or store this appliance in any location where it could be exposed to water and or weather.
Save these instructions.
(Installers: Be sure to leave these instructions with the customer).
BEFORE YOU BEGIN-
Read these instructions completely and carefully
Important
- Save these instructions for local inspector's use.
Important
- Observe all governing codes and ordinances.
Note to Installer - Be sure to leave these instructions with the customer.
Note to Customer
- Keep these instructions for local inspector's use.
Before the old dryer is removed from service or discarded, remove the dryer door.
Service information and the wiring diagram are located in the control console.
Do not allow children on or in the appliance.
Close supervision is necessary
when the appliance is used near children.
Install the dryer where the temperature
is above 50°F for satisfactory
operation of the dryer control system.
Preparing
the Installation
Site and Unpacking
the Dryer
1.Prepare the area and exhaust for installation of the new dryer.
2.Check to be sure that the existing external exhaust is clean and that it meets
attached installation specifications.
3.Using the four shipping carton corner posts as padding (two on each side),
carefully lay the dryer on its left side and remove foam shipping pad.
4. Return the dryer to an upright position.
5. Move the dryer to the desired location.
Tools and Materials
you will need
[] Slip joint pliers
[] Screwdrivers (slotted or phillips
head)
[] Chains (x2)
[] 2"x 4" studs
[] Wall hoods
[] Two 3/4" UL recognized strain
relief if the power supply is
from a direct wire.
[] Two dryer power cord kit UL
listed, rated 120/240V, 30A with
3 or 4 prongs if the power
supply is from a wall receptacle.
[] 4" diameter rigid metal duct,
duct clamps, elbows and
exhaust hood.
[] Basic safety protection such as
safety goggles, gloves and arm
protection are recommended.
INSTALLATION
_
_llL
",IL
_lL
",11_ "_IL
_IL
"lh=
_,IL.
"qllL "_L
_qL
"qlh,. "IL
",1_
_llL
_
"IL
"IlL
_lL.
_
F
j ,_4_CAUTION: FOR PERSONAL
SAFETY,
STACKED
j
. UNITS
MUST BE FASTENED
SECURELY
TO WALL.
.,
STEP 1
Attach two chains using Phillips
head screws
to each end of
upper section
of cabinet
(upper unit).
STEP 2
Locate two wall studs behind desired
operating
location of
stacked
units.
NOTE: For wall studs
not appropriately
spaced,
see section
for Alternate
Method for Installation
of Wall Hooks.
STEP 3
Screw two wall hooks into two wall studs (same height as
chain connections
on cabinet
of upper unit). Both chains
should
pull straight
back to wall studs or angle outward.
NEITHER
chain should
angle inward.
NOTE: The final construction
must withstand
a
of 200 Ibs.
REAR ViEW
ATTACH CHAINS
HERE
::
}
WALL
500A436POO3RevO
Pub.#31-16222

Advertisement

loading

Summary of Contents for GE 31-16222

  • Page 1 Screw two wall hooks into two wall studs (same height as chain connections on cabinet of upper unit). Both chains should pull straight back to wall studs or angle outward. NEITHER chain should angle inward. NOTE: The final construction must withstand of 200 Ibs. 500A436POO3RevO Pub.#31-16222...
  • Page 2 iNSTALLATiON (continued) STEP 4 Connect both dryers to power supply. (See ELECTRICAL CONNECTION INFORMATION section of this instruction.) SiDEWEW STEP 5 Connect both dryers to external exhaust. (See EXHAUST INFORMATION of this instruction.) STEP 6 Hook both chains from upper unit to appropriate wall hooks taking up any slack.
  • Page 3 CONNECTING DRYER USING 4-WIRE CONNECTION REMOVE GROUND STRAP AND DISCARD ,, Remove the cover near the power cord entry hole. KEEP GREEN GROUND SCREW ,, Install 3/4" UL recognized strain relief to power strain relief cord entry hole. Bring power cord through strain -sRELOCATE GREEN GRouND_ bracket...
  • Page 4 EXHAUST iNFORMATiON (continued) EXHAUST SYSTEM CHECK LiST TURNS OTHER THAN 90 ° HOOD OR WALL CAP • One turn of 45 ° or less may be ignored. • Two 45 ° turns should be treated as one 90 ° • Terminate in a manner to prevent back drafts or •...