Ericsson EDACS Station GETC1e 19D901868G4 Configuration Manual
Ericsson EDACS Station GETC1e 19D901868G4 Configuration Manual

Ericsson EDACS Station GETC1e 19D901868G4 Configuration Manual

Edacs station getc1e
Table of Contents

Advertisement

Quick Links

LBI-38988B
Configuration Manual
EDACS Station GETC1e
19D901868G3 and G4

Advertisement

Table of Contents
loading

Summary of Contents for Ericsson EDACS Station GETC1e 19D901868G4

  • Page 1 LBI-38988B Configuration Manual EDACS Station GETC1e 19D901868G3 and G4...
  • Page 2: Revision History

    Ericsson Inc., at any time and without notice. Such changes will be incorporated into new editions of this manual. No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, for any purpose, without the express written permission of Ericsson Inc.
  • Page 3: Table Of Contents

    LBI-38988 TABLE OF CONTENTS Page REVISION HISTORY..........................2 INTRODUCTION.............................6 SOFTWARE FEATURES ........................6 349A9607G5 SOFTWARE ........................6 SCAT Data ...........................6 Pro-Sound .............................6 Enhanced Multi-Site Login ......................7 Voted Digital Interconnect ......................7 DIP Switch Changes........................8 349A9607G4 SOFTWARE ........................8 Multisite Digital Voice or Digital Data..................8 RELATED PUBLICATIONS........................9 SOFTWARE COMPATIBILITY......................9 GETC EPROM and TURBO BOARD SOFTWARE COMPATIBILITY..........9 EDACS COMPONENT SOFTWARE COMPATIBILITY ..............9...
  • Page 4 LBI-38988 TABLE OF CONTENTS Page DIP Switch Settings ........................26 Fully Trunked System ........................26 Failsoft System..........................27 Satellite Site Receiver ........................28 INTERFACE SIGNALS ........................28 TROUBLESHOOTING ........................... 29 FAILURE MODE..........................29 CHANNEL ACTIVITY LOGGER....................... 29 IN CASE OF DIFFICULTY ........................ 29 INTERCONNECT DIAGRAMS......................
  • Page 5 LBI-38988 LIST OF TABLES Page Table 1 - GETC EPROM and Turbo Software Compatibility ..........9 Table 2 - EDACS Component Software Compatibility............10 Table 3 - Radio Compatibility....................10 Table 4 - GETC Hardware Compatibility................11 Table 5 - Indicators in Programming Mode Using J100 ............22 Table 6 - Indicators in Programming Mode Using J104 ............23 Table 7 - Sample Station Personality ...................24 Table 8 - Channel Number Switch Settings .................26...
  • Page 6: Introduction

    The 349A9607G5 software release adds the following This manual provides instructions for configuring the features to GETC operation: Ericsson GE Trunking Card Shelf (GETC ), part number 19D901868G3 and G4, for Station (including repeater and SCAT Data (Refer to LBI-38987) SCAT), Satellite Site Receiver, and VDI Control operation.
  • Page 7: Enhanced Multi-Site Login

    MOM PC, which is connected to the IMC. accompanying Station Turbo Software distribution disk or from Ericsson’s “One1Call” Enhanced Multi-Site Login Electronic Information Retrieval system. The Enhanced Multi-Site Login feature provides a method to enhance signaling integrity, on both the inbound...
  • Page 8: Dip Switch Changes

    LBI-38988 SOFTWARE FEATURES capability of listening to both the IMC and the Voter In earlier software versions, the operating frequency simultaneously. for MII/IIe systems was set into the DIP switches. With the introduction of 349A9607G5 the MII/IIe and MIII systems For a Simulcast system, no additional equipment is frequency is programmed in personality.
  • Page 9: Related Publications

    RELATED PUBLICATIONS LBI-38988 Table 1 - GETC EPROM and Turbo Software RELATED PUBLICATIONS Compatibility It may be necessary to consult one or more of the following documents during the installation process. These GETC LOGIC BOARD TURBO BOARD manuals will also provide additional guidance if you EPROM, U2 SOFTWARE encounter technical difficulties during the configuration...
  • Page 10: Radio Compatibility

    LBI-38988 SOFTWARE COMPATIBILITY RADIO COMPATIBILITY Table 3 describes the minimum software requirements for radio products supporting the features included in this release. Table 2 - EDACS Component Software Compatibility EDACS COMPONENT Required for Required for Required for Required for Required for SCAT Data Enhanced ProSound...
  • Page 11: Hardware Compatibility

    HARDWARE COMPATIBILITY LBI-38988 NOTE HARDWARE COMPATIBILITY NOTE GETCs using EPROM 349A9607G4 or later must The GETC hardware compatibility depends on the use Logic Board 19D904266G4 or upgrade the version of EPROM installed on the Logic Board, refer to Logic Board 19D904266G1 with the Speedup the following table: (80C320) microprocessor and Amps Modem Table 4 - GETC Hardware Compatibility...
  • Page 12: Description

    LBI-38988 DESCRIPTION CONTROL CHANNEL DESCRIPTION The Station GETC is the foundation of all EDACS The Control Channel GETC provides continuous trunking operations. It is capable of operating in the outbound Control Channel data. The data stream consists Trunked Failsoft mode or as part of a fully trunked system of message frames containing information such as Channel or network.
  • Page 13: Station Control

    LBI-38988 whenever the communications between the Site Controller TX MOD (J7-4) Direct modulation input to the and the Control Channel GETC is lost. synthesizer-exciter (MIIe only). STATION CONTROL GETC DATA (J7-5) Input to the transmitter for The Station GETC controls the Repeater Station's filtered High Speed Data radio through the following interface and control lines: (HSD) to be transmitted.
  • Page 14: Configuration

    LBI-38988 CONFIGURATION Installation or removal of the shelf sub-assemblies CONFIGURATION involves sliding the GETC shelf out of the cabinet and into The configuration process involves the following the service position. This position allows access to the procedures and should be completed in the order presented: shelf's sub-assemblies.
  • Page 15: Rockwell Modem Installation

    CONFIGURATION LBI-38988 Parallel Data Bus Receiving Half of Transmitting Half of TP107 TP105 Telephone Line Telephone Line Demodulated Unmodulated J6-07 J6-06 Rx Data Tx Data J6-09 J6-08 Serial Data Rockwell Modem 19A705178 R146 J3C-24 J3C-22 U18A U18B J3A-31 J3A-32 4558 4558 Level Level...
  • Page 16: Figure 4 - Station Getc (19D904266) Jumper And Test Point Locations

    LBI-38988 CONFIGURATION Figure 4 - Station GETC (19D904266) Jumper and Test Point Locations Rev. B...
  • Page 17: Getc Software Installation

    CONFIGURATION LBI-38988 2. If upgrading from 19A149256G21 (or earlier) GETC SOFTWARE INSTALLATION software, remove RAM chip U3 and install Turbo The GETC software installation procedure involves Board. Refer to LBI-38822 for instructions. installing the latest version of the EPROM containing the GETC operating software.
  • Page 18: Fully Trunked Systems

    LBI-38988 CONFIGURATION this manual and the detailed instructions contained Replace if necessary. Refer to LBI-38894 for in TQ-3357 and SRN1060. installation instructions. 15. Perform an operational checkout using the Failsoft 7. Ensure Turbo Board harness has Ferrite Toroid System checkout procedures. installed.
  • Page 19: Satellite Receivers & Simulcast Remote Tx

    CONFIGURATION LBI-38988 Speedy Upgrade Kit. Replace if necessary. Refer Satellite Receivers & Simulcast Remote TX to LBI-38822 for installation instructions. Perform the following steps when installing the software in a GETC connected in a Voted system as a 6. Remove the old EPROM (U2) from the GETC Satellite Site Receiver or at the Remote TX Site.
  • Page 20: De-Installing The Getc-1E Software

    LBI-38988 CONFIGURATION When using PC Programmer TQ-3357 V3 (or earlier) De-installing The GETC-1e Software and downloading 344A4414G3 (and earlier) software, the If a problem arises while upgrading or installing the data from the PC files is routed to the Turbo Board new software, it may be necessary to de-install the software.
  • Page 21: Pc Programmer Setup

    CONFIGURATION LBI-38988 NOTE PC Programmer Setup NOTE When using Turbo Board 344A4414 Group 2 (or Prepare the PC for programming the GETC Turbo later) software, re-programming the GETC Turbo Board by performing the following steps: Board will not alter previously stored Personality Data.
  • Page 22: Programming A Personality Using Tq-3357 Version 4.03 (Or Later)

    LBI-38988 CONFIGURATION of the serial cable to the GETC Shelf connector J100, see Figure 5. 2. Set the GETC DIP switches S1, S2, and S3 for the programming mode as shown in Figure 6. Set S2- OPEN OPEN OPEN 8, S3-3 and S3-6 to OPEN. All other S3 positions should be CLOSED.
  • Page 23: Figure 7 - System Hook-Up Using J104

    CONFIGURATION LBI-38988 3. Verify that front panel LEDs L6 and L7 are 4. Proceed with the Personality programming as flashing, as shown in Table 6. This indicates the described in TQ-3357. GETC is ready for programming. 5. After saving the personality and downloading it into the GETC, perform an operational checkout Table 6 - Indicators in Programming Mode Using J104 of the GETC.
  • Page 24: Table 7 - Sample Station Personality

    LBI-38988 CONFIGURATION Table 7 - Sample Station Personality Personality: C:\GE\GTC\PERS\SAMPLE.GTC ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Personality Description This is a sample personality for a Station GETC. Channel Allocations 11111 11111 22222 22222 Channel Number 1234 56789 01234 56789 01234 56789 Control Channel YYYY YYYYY YYYYY YYYYY Y..
  • Page 25 Field Macro(s) is installed into the PC Programmer. Field Macros keep the programmer current until a fully upgraded PC Programmer which includes all features is made available. The Field Macros are supplied with the Turbo Software Media Kit and may be downloaded from Ericsson’s “One1Call” retrieval system.
  • Page 26: Operational Checkout

    LBI-38988 OPERATIONAL CHECKOUT 6. Set S3-1 thru S3-5 to the Channel Address. Refer OPERATIONAL CHECKOUT to Table 8. Verify that the GETC is operating correctly by performing the following steps: 7. Set S3-6 to CLOSED. DIP Switch Settings 8. Set S3-7 OPEN for Simulcast or CLOSED for non-Simulcast.
  • Page 27: Failsoft System

    OPERATIONAL CHECKOUT LBI-38988 2. Place test calls from radios in Channel Test by Failsoft System keying one of the test radios and monitoring the Perform the following steps to verify operation of a audio from the other radio. Place Clear Voice GETC used in a Failsoft System: calls and if programmed, Digital Voice calls.
  • Page 28: Satellite Site Receiver

    LBI-38988 OPERATIONAL CHECKOUT Table 12 - LED Indicators for Failsoft Assigned Table 13 - LED Indicators for Satellite Site Receivers Channels LED Indicators L1 L2 L3 L4 L5 L6 L7 LED Indicators L1 L2 L3 L4 L5 L6 L7 WB Working Channel Failsoft Assigned WB Satellite Site Idle Clear Call...
  • Page 29: Troubleshooting

    IN CASE OF DIFFICULTY If you are unable to resolve a problem to your FAILURE MODE satisfaction, then contact the Ericsson Technical Assistance Center (TAC) at 1-800-528-7711 (outside USA, 804-528- With the introduction of 349A9607 Group 4 software, 7711). the GETC is able to indicate a specific failure via the front...
  • Page 30: Table 15 - Interface Status During Various States

    LBI-38988 TROUBLESHOOTING Table 15 - Interface Status During Various States SIGNAL STATE STATUS Control Channel: Vol/Sq (J7-2) Data High Speed signaling is being routed to the HSD Detector. RUS In (J7-14) High Receiver is unsquelched and watching carrier activity for the presence (present = Low) of an interfering signal (without valid signaling).
  • Page 31 TROUBLESHOOTING LBI-38988 Table 15 - Interface Status During Various States (Continued) SIGNAL STATE STATUS Working Channel (Active): Handshake Mode Vol/Sq (J7-2) Data Listening to High Speed handshake. RUS In (J7-14) RUS activity is being ignored during the handshake. Rus Out (J7-15) Receiver is muted (no receiver audio to the transmitter) until call is validated.
  • Page 32 LBI-38988 TROUBLESHOOTING Table 15 - Interface Status During Various States (Continued) SIGNAL STATE STATUS Working Channel (Active): During Digital Call Vol/Sq (J7-2) Analog Digital Voice data on this line. RUS In (J7-14) Carrier activity is ignored during Digital Voice call. Rus Out (J7-15) Receiver is muted.
  • Page 33: Interconnect Diagrams

    INTERCONNECT DIAGRAMS LBI-38988 J100 19C336863G1 Site Controller 19C320811 (MASTR II/IIe) (MSL) 19B802401 (MASTR III) Lightning GETC 19D904266 J102 Other GETCs Delay PTT BSL RxD (BSL) Phone Rx Phone Rx BSL TxD Phone Tx Phone Tx Det Dis (MIII) DATA (MII) P1 9 J 1 9 CLK (MII)
  • Page 34 LBI-38988B INTERCONNECT DIAGRAMS MASTR III STATION INTERCONNECT Rev. B...
  • Page 35 LBI-38988 Serial Link to Failsoft GETC Data Site Controller, Downlink GETC, to Downlink GETC and other Station GETC's and other Station GETC's J100 J102 GETC 19D901868 GETC Logic Board 19D904266 SYNC DATA DATA MODEM +13.8 V LOCK Data Delay VOL/SQ DATA P/O Harness 19C320811...
  • Page 36: Parts List

    LBI-38988B GETC CABLE 19C336863G1 SYMBOL PART DESCRIPTION NUMBER ------------------ JACKS ------------------ J100 19B209727P18 Connector: 9 contacts; sim to AMP thru 205203-1. J102 ----------------- PLUGS ----------------- 19A700041P32 Shell: 6-Position; sim to Molex 22-01- 2065. 19A700041P32 Shell: 6-Position; sim to Molex 22-01- 2065.
  • Page 37: Cable Diagrams

    LBI-38988 GETC CABLE 19C336863G1 (19C336863, Sh. 1, Rev. 4; 19C336866, Sh. 1, Rev. 0) Rev. B...
  • Page 38 LBI-38988B This page intentionally left blank Rev. B...
  • Page 39 800 MHZ FREQUENCY SELECTIONS LBI-38988 APPENDIX A 800 MHZ EDACS APPLICATIONS FREQUENCY SELECTIONS GETC DIP SWITCH SETTINGS NOTE NOTE For MASTR II/IIe using Station GETC software 349A9607G4 (or earlier) only. For MASTR II, IIe, and III using 349A9607G5 (or later), set switches S1-1 thru S1-7 and S2-1 thru S2-4 to the CLOSED position Rev.
  • Page 40 LBI-38988 800 MHZ FREQUENCY SELECTIONS S1-1 S2-1 S1-1 S2-1 S1-1 S2-1 TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 851.5125 1001100 1000 852 MHz 851 MHz 851.5250 0101100 1000 852.0000...
  • Page 41 800 MHZ FREQUENCY SELECTIONS LBI-38988 S1-1 S2-1 S1-1 S2-1 S1-1 S2-1 TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 852.4875 1110011 1000 852.9875 1111000 0100 853.4750 0110110 0100 853.4875 1110110...
  • Page 42 LBI-38988 800 MHZ FREQUENCY SELECTIONS S1-1 S2-1 S1-1 S2-1 S1-1 S2-1 TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 854.5000 0001000 1100 855 MHz 854 MHz 854.5125 1001000 1100 855.0000...
  • Page 43 800 MHZ FREQUENCY SELECTIONS LBI-38988 S1-1 S2-1 S1-1 S2-1 S1-1 S2-1 TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 855.5000 0001101 1100 856.5000 0001010 0010 856 MHz 855.5125 1001101 1100...
  • Page 44 LBI-38988 800 MHZ FREQUENCY SELECTIONS S1-1 S2-1 S1-1 S2-1 S1-1 S2-1 TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 857.5000 0001111 0010 857 MHz 858 MHz 857.5125 1001111 0010 857.0000...
  • Page 45 800 MHZ FREQUENCY SELECTIONS LBI-38988 S1-1 S2-1 S1-1 S2-1 S1-1 S2-1 TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 858.5000 0001001 1010 859.5000 0001100 0110 859 MHz 858.5125 1001001 1010...
  • Page 46 LBI-38988 800 MHZ FREQUENCY SELECTIONS S1-1 S2-1 S1-1 S2-1 S1-1 S2-1 TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 860.5000 0001011 0110 860 MHz 861 MHz 860.5125 1001011 0110 860.0000...
  • Page 47 800 MHZ FREQUENCY SELECTIONS LBI-38988 S1-1 S2-1 S1-1 S2-1 S1-1 S2-1 TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 861.5000 0001110 1110 862.5000 0001000 0001 862 MHz 861.5125 1001110 1110...
  • Page 48 LBI-38988 800 MHZ FREQUENCY SELECTIONS S1-1 S2-1 S1-1 S2-1 S1-1 S2-1 TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 863.5000 0001101 0001 863 MHz 864 MHz 863.5125 1001101 0001 863.0000...
  • Page 49 800 MHZ FREQUENCY SELECTIONS LBI-38988 S1-1 S2-1 S1-1 S2-1 S1-1 S2-1 TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 864.5000 0001010 1001 865.5000 0001111 1001 865 MHz 864.5125 1001010 1001...
  • Page 50 LBI-38988 800 MHZ FREQUENCY SELECTIONS S1-1 S2-1 S1-1 S2-1 S1-1 S2-1 TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 866.5000 0001001 0101 866 MHz 867 MHz 866.5125 1001001 0101 866.0000...
  • Page 51 800 MHZ FREQUENCY SELECTIONS LBI-38988 S1-1 S2-1 S1-1 S2-1 S1-1 S2-1 TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 867.5000 0001100 1101 868.5000 0001011 1101 868 MHz 867.5125 1001100 1101...
  • Page 52 LBI-38988 800 MHZ FREQUENCY SELECTIONS S1-1 S2-1 S1-1 S2-1 S1-1 S2-1 TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 869.5000 0001110 0011 869 MHz 869.5125 1001110 0011 869.0000 0000100 0011...
  • Page 53 900 MHZ FREQUENCY SELECTIONS LBI-38988 APPENDIX B 900 MHZ EDACS APPLICATIONS FREQUENCY SELECTIONS GETC DIP SWITCH SETTINGS NOTE NOTE For MASTR II/IIe using Station GETC software 349A9607G4 (or earlier) only. For MASTR II, IIe, and III using 349A9607G5 (or later), set switches S1-1 thru S1-7 and S2-1 thru S2-4 to the CLOSED position Rev.
  • Page 54 LBI-38988 900 MHZ FREQUENCY SELECTIONS S1-1 S2-1 S1-1 S2-1 S1-1 S2-1 TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 935.5125 1001010 0000 935 MHz 936 MHz 935.5250 0101010 0000 935.0125...
  • Page 55 900 MHZ FREQUENCY SELECTIONS LBI-38988 S1-1 S2-1 S1-1 S2-1 S1-1 S2-1 TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 936.5000 0001111 0000 937.5000 0001001 1000 937 MHz 936.5125 1001111 0000...
  • Page 56 LBI-38988 900 MHZ FREQUENCY SELECTIONS S1-1 S2-1 S1-1 S2-1 S1-1 S2-1 TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 938.5000 0001100 0100 938 MHz 939 MHz 938.5125 1001100 0100 938.0000...
  • Page 57 900 MHZ FREQUENCY SELECTIONS LBI-38988 S1-1 S2-1 S1-1 S2-1 S1-1 S2-1 TX FREQ Thru Thru TX FREQ Thru Thru TX FREQ Thru Thru (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 (MHz) S1-7 S2-4 939.5000 0001011 0100 939.5125 1001011 0100 939.5250 0101011 0100 939.5375 1101011...
  • Page 58 LBI-38988 Ericsson Inc. Private Radio Systems Mountain View Road Lynchburg, Virginia 1-800-528-7711 (Outside USA, 804-528-7711) Printed in U.S.A.

This manual is also suitable for:

19d901868g3