Honeywell VISTA-128FBP User Manual page 20

Commercial fire and burglary partitioned security systems with scheduling
Hide thumbs Also See for VISTA-128FBP:
Table of Contents

Advertisement

Security Codes and Authority Levels (cont'd)
MULTI-ACCESS ?
0 = NO , 1 = YES
GLOBAL ARM ?
0 = NO , 1 = YES
PART.2 - SHOP?
0 = NO , 1 = YES
PART. 1 A0* WHSE
USER 003 AUTH=3G.
– 20 –
If you as a user have access to other partitions, the
keypad will prompt for ability of this new user to
access (GOTO) those partitions. Press 0 (NO) or 1
(YES). If no, the system activates this user code and
exits "Add a User" mode. If yes, the keypad prompts
for the Global Arm option for this user.
Press 1 (YES) if this user will be allowed to try to
arm more than one partition at the same time.
Press 0 if this user will arm only his assigned
partition.
The keypad now prompts for the user's access to the
next partition (see GOTO command). Again press 0
or 1. If yes, the system will automatically assign a
user number for use in that partition and will
prompt for authority level and global arm options
for this user within the partition (see previous
steps).
When all partitions have been displayed, the
keypad will scroll through the partition(s) to which
access has been assigned, and will display the user
number, authority level and global arm option for
each. The "G" after the authority level indicates
that the global arm feature is active for this user
in the displayed partition. The "*" indicates the
partition from which this user can be changed or
deleted. The "." at the end of the second line
indicates that this user sends open/close reports.
Open/close reporting is automatically active for
any users added by you, if you have open/close
reporting active.

Hide quick links: