Connector (Terminal); Communication - AND Profibus Interface AD-4402 OP-22 Instruction Manual

Profibus interface
Table of Contents

Advertisement

3.1.3.
3.1.3.
3.1.3.
3.1.3.

Connector (Terminal)

Connector (Terminal)
Connector (Terminal)
Connector (Terminal)
The pin connections are as follows:
Pin No.
1
SHIELD
2
-
3
RxD/TxD-P
4
CNTR-P
5
DGND
6
VP
7
-
8
RxD/TxD-N
9
-
3.1.4.
3.1.4.
3.1.4.
3.1.4.

Communication

Communication
Communication
Communication
Modes Supported (Global Control Service)
SYNC mode and FREEZE mode are supported.
Diagnostic Data
Diagnostic data uses six bytes specified as DP standard. The rated paramters adapt
to the diagnostic report specified at EN 50 170.
Connection to PROFIBUS
Use bus termination.
Maximum cable length according to transmission speed.
Baud rate
9.6
19.2
93.75
187.5
500
1.5
3
6
12
Use authorized cables and connectors designed for PROFIBUS .
AD-4402 OP-22
Signal
Protective ground
Not connected
Receive / send data, Data line B
RTS (Request To Send)
Data ground
Power supply
Not connected
Receive / send data, Data line A
Not connected
Maximum cable length for type A cable
kbps
kbps
kbps
kbps
kbps
Mbps
Mbps
Mbps
Mbps
Description
1200m
1200m
1200m
1000m
400m
200m
100m
100m
100m