Summary of Contents for 3M Dynapro ET 3170 Terminal Series B

  • Page 1 ET 3170 Terminal (Series B) User’s Installation Guide Read and understand all safety information before installing and using this product. 3M Touch Systems Proprietary Information...
  • Page 2 3M Touch Systems, a subsidiary of 3M, is prohibited. Notice Given the variety of factors that can affect the use and performance of a 3M Touch Systems Product (the “Product”), including that solid state equipment has operation characteristics different from electromechanical equipment, some of which factors are uniquely within User’s knowledge and control, it is essential...
  • Page 3: Important Safety Information

    Intended use The 3M Dynapro ET 3170 terminal is intended to provide touch screen functions for industrial applications when the terminal is connected to a host computer. The ET 3170 terminal is not intended for use in hazardous locations. Using the terminal in conditions exceeding these ratings will invalidate the warranty and will be solely the user’s risk and responsibility.
  • Page 4 Do not use an ET unit that is not rated to NEMA 4X/IP66 in an environment that requires a NEMA 4X/IP66 seal. When replacing a fuse of other part, use a part of the type and rating specified by 3M Touch Systems.
  • Page 5 Important Safety Information Safety labels The following safety symbols appear on your 3M Dynapro industrial product and its packaging materials: Symbol Meaning Consult user instructions. Caution: Risk of electric shock. Caution: Item is susceptible to electrostatic discharge (ESD) damage if proper precautions are not taken.
  • Page 7: Information Importante

    Utilisation Le terminal Dynapro ET 3170 de 3M est conçu pour servir à l’exécution de fonc- tions au moyen d’un écran tactile dans les utilisations industrielles où le terminal est raccordé à un ordinateur hôte. Le terminal Dynapro ET 3170 n’est pas destiné...
  • Page 8 Guide d’installation et d’utilisation du terminal Dynapro ET 3170 de 3M AVERTISSEMENT Pour réduire les risques d’incendie et d’électrocution susceptibles, faute de précau- tion, de causer la mort, des blessures graves ou des dommages matériels : Fournir une mise à terre fiable et propre.
  • Page 9 Information importante sur la sécurité Étiquettes de sécurité Les symboles de sécurité suivants apparaissent sur le produit industriel Dynapro de 3M et sur son emballage : Symbole Signification des symboles Consulter le mode d’emploi. Avertissement : Risque d’électrocution. Avertissement : À défaut de prendre des mesures de précaution appropriées, le produit risque de subir des dommages par suite...
  • Page 11 Belangrijke veiligheidsinformatie Voordat de 3M Dynapro™ ET 3170 terminal wordt gebruikt, moet alle veilig- heidsinformatie zijn gelezen en begrepen. Volg alle op het product aangegeven en in dit document beschreven instructies op. Besteed extra aandacht aan de verkla- ring betreffende het voorgenomen gebruik en de veiligheidskennisgevingen.
  • Page 12 NEMA 4X/IP66-afdichting vereist is. Gebruik ter vervanging van zekeringen of andere onderdelen uitsluitend onderdelen van het type en met de toegestane waarde die door 3M Touch Systems zijn opgegeven. WAARSCHUWING Neem het volgende in acht om de risico’s van elektrische schokken te reduceren die,...
  • Page 13 Voer de ET-eenheid af in overeenstemming met de van toepassing zijnde overheidsbepa- lingen. Veiligheidslabels De volgende veiligheidssymbolen staan op het industriële 3M Dynapro product en de verpakkingsmaterialen: Symbool Betekenis Raadpleeg de instructies voor de gebruiker.
  • Page 15: Wichtige Sicherheitshinweise

    Wichtige Sicherheitshinweise Bevor Sie das 3M Dynapro™ ET 3170 Terminal benutzen, müssen Sie alle Si- cherheitshinweise gelesen und verstanden haben. Befolgen Sie alle am Produkt angebrachten und in diesem Dokument beschriebenen Anweisungen. Achten Sie insbesondere auf die Erklärung zum Einsatzbereich und die Sicherheitshinweise.
  • Page 16 Ein ET-Gerät, das nicht für NEMA 4X/IP66 ausgelegt ist, in nicht einer Umgebung einset- zen, die eine NEMA 4X/IP66-Dichtung erfordert. Beim Ersetzen einer Sicherung oder eines anderen Bauteils muss das Teil dem Typ und den Nenndaten entsprechen, die von 3M Touch Systems festgelegt wurden. WARNHINWEISE Um Elektroschockgefahr mit möglichen schweren Verletzungs- oder Todesfolgen und/oder Sachschäden zu vermeiden:...
  • Page 17 Um die Gefahr der Umweltbelastung mit möglichen leichten oder moderaten Verlet- zungsfolgen und/oder Sachschäden zu vermeiden: Das ET-Gerät entsprechend den geltenden gesetzlichen Vorschriften entsorgen. Sicherheitssymbole Die folgenden Sicherheitssymbole sind auf Ihrem 3M Dynapro und dessen Ver- packung abgebildet: Symbole Bedeutung der Symbole Lesen Sie bitte in der Bedienungsanleitung nach.
  • Page 19 Si prega di leggere ed assimilare bene tutte le norme di sicurezza prima di utiliz- zare il terminale Dynapro™ ET 3170 di 3M. Seguire tutte le istruzioni indicate sul prodotto e descritte nel presente documento. Si prega di leggere con particolare at- tenzione la dichiarazione relativa alla destinazione d’uso e le avvertenze di sicu-...
  • Page 20 Guida all’Installazione del Terminale ET 3170 Dynapro di 3M per l’Utente AVVERTENZA Per ridurre i rischi associati ad incendio ed esplosione che, se non evitati, possono causare la morte o il ferimento grave di persone e/o il danneggiamento di cose: Programmare l’installazione dell’unità...
  • Page 21 Smaltire l’unità ET secondo le vigenti norme locali. Etichette di sicurezza Sul vostro prodotto industriale Dynapro 3M e sul relativo materiale da imballag- gio saranno esposti i seguenti simboli: Simboli Significato dei simboli Consultare le istruzioni per l’utente...
  • Page 23 Lea y comprenda la información completa de seguridad antes de utilizar la Termi- nal 3M Dynapro™ ET 3170. Siga las instrucciones marcadas en el producto y que se describen en este documento. Preste mucha atención a la indicación sobre el propósito del producto y los avisos de seguridad.
  • Page 24 Guía del usuario para la instalación de la Terminal 3M Dynapro ET 3170 ADVERTENCIA Para reducir los riesgos asociados con choque eléctrico o incendios, los cuales, si no se evitan, pueden ocasionar la muerte o serias lesiones o daños a la propiedad: Proporcione una tierra limpia y confiable.
  • Page 25 Deseche la unidad ET de acuerdo con la reglamentación gubernamental que aplique. Etiquetas de seguridad Los siguientes símbolos de seguridad aparecen en el producto industrial y en los materiales de empaque de 3M Dynapro: Símbolo Significado de los símbolos Consulte las instrucciones para el usuario.
  • Page 27 3M Dynapro ET 3170 Terminal 3M Dynapro ET 3170 Terminal ET 3170 Terminal ET 3170 Terminal 3M Touch Systems 3M Touch Systems...
  • Page 28 3M Dynapro ET 3170 Terminal NEMA 4X/IP66 NEMA 4X/IP66 NEMA 4X/IP66 3M Touch Systems 3M Touch Systems xxvi...
  • Page 29 3M Dynapro 3M Touch Systems xxvii...
  • Page 31: Table Of Contents

    Contents Before you start About the User’s Installation Guide.......... 1 About this guide....................1 Related documents....................2 3M Touch Systems support services ..............3 Chapter 1 Introducing the ET 3170 terminal ..........5 Introducing the terminal ..................5 Features......................... 5 Configuration overview ..................
  • Page 33 Table I: Effects of New Line Parameter on characters sent to host ....38 Table J: Effects of New Line Parameter on characters sent from host ..... 38 Table K: Tests available from the Test screen pages ........40 3M Touch Systems Proprietary Information xxxi...
  • Page 35 Figure 21: Stored Screens Test screen............... 45 Figure 22: Static ASCII Character Font Test screen ......... 47 Figure 23: Static Special Character Font Test screen........48 Figure 24: Components ..................55 Figure 25: Enclosure dimensions ..............56 3M Touch Systems Proprietary Information xxxiii...
  • Page 37: Before You Start About The User's Installation Guide

    If the label on your unit indicates that it is a Series A terminal, you have an earlier version of the product and you should refer to the 3M Dynapro ErgoTouch 3170 TCS Terminal Installation Guide (document 11754). This document may be downloaded from www.3Mtouch.com.
  • Page 38: Related Documents

    3M Dynapro ET 3170 Terminal User’s Installation Guide What is included Here is a summary of topics covered in the manual: For information on: Refer to: Features Chapter 1 Unpacking Chapter 2 Making connections Chapter 3 Mounting Chapter 4 Configuring (using the Setup screen)
  • Page 39: 3M Touch Systems Support Services

    About the User’s Installation Guide 3M Touch Systems support services 3M Touch Systems provides extensive support services through our web site and technical support organization. Visit www.3Mtouch.com, to download touch screen software and drivers, obtain regularly updated technical documentation on 3M Touch Systems products, and learn more about our company.
  • Page 40: M Touch Systems Worldwide Offices

    3M Dynapro ET 3170 Terminal User’s Installation Guide 3M Touch Systems Worldwide Offices All offices can be reached through the web site: www.3Mtouch.com. Country Telephone United Kingdom 978-659-9000 United States 978-659-9000 Australia +61 395-82-4799 Canada 604-521-3962 France +33 (1) 45-13-90-30...
  • Page 41: Introducing The Et 3170 Terminal

    CHAPTER 1 Introducing the ET 3170 terminal About this chapter This chapter provides an overview of the 3M Dynapro ET 3170 terminal (Series B), including: Features of the terminal. Options available for configuring (customizing) the terminal for your application. Introducing the terminal...
  • Page 42: Configuration Overview

    The backlight and extending its life The typical life expectancy of the backlight is 50,000 hours. A Backlight Replacement Kit (including instructions) is available from 3M Touch Systems. You can extend the life of the display and backlight by setting them to turn off automatically after 30 minutes of inactivity.
  • Page 43: Unpacking The Terminal

    The information in the Service Guide is intended only for qualified service personnel. NEMA 4X Panel Gasket Kit (including panel gasket installation instructions) Full-scale cutout template Panel mount screws (24 screws; two sizes, 12 of each) AC power cable (standard cable suitable for North American applications) 3M Touch Systems Proprietary Information...
  • Page 45: Installing The Terminal

    4. If the unit performs as described, disconnect power and proceed with the “Summary of installation steps” below. If you encountered any problems during the pre-installation check, refer to Chapter 7, “Troubleshooting”. If problems persist, contact 3M Touch Systems Technical Support. 3M Touch Systems Proprietary Information...
  • Page 46: Summary Of Installation Steps

    3M Dynapro ET 3170 Terminal User’s Installation Guide Summary of installation steps 1. Decide where you want to install the terminal. For guidelines on locating the terminal, see “Guidelines” on page 17. DANGER To reduce the risks associated with fire and explosion which, if not avoided, will cause death or serious injury and/or property damage: Do not install or use the ET unit in a hazardous location.
  • Page 47: Connectors

    You can use standard cables for all connections, except for the RS-422/485 connection through the communication port. Connector pin-outs are provided in this section if you choose to make your own cables. Keyboard connector Serial port Fuse Power connector 73174 Figure 2: Terminal connectors 3M Touch Systems Proprietary Information...
  • Page 48: Connecting A Serial Device

    3M Dynapro ET 3170 Terminal User’s Installation Guide Connecting a serial device The terminal has one asynchronous serial port that can be used to connect to your host system. This port is 16550 UART-based and can transmit data at speeds up to 19,200 baud.
  • Page 49: Connecting A Keyboard (Optional)

    However, if you want to use a keyboard with the terminal, you can connect a 101- key Enhanced PC/AT compatible keyboard to the female DIN plug inside the rear hatch. Use a standard cable, or construct a cable matching the pin-out in Table D. 3M Touch Systems Proprietary Information...
  • Page 50: Connecting Ac Power

    For North American applications, use a standard AC power cable (Figure 4) Both types of AC power cable are available from 3M Touch Systems and come with either: IEC connector Fixed field wiring...
  • Page 51: Figure 3: Connecting Power: Ac Power Cable With Iec Connector

    4. Insert the stripped end of the AC power cable wire (neutral) into the terminal strip’s side connector (Figure 4). 3M Touch Systems Proprietary Information...
  • Page 52: Figure 4: Connecting Ac Power Cable Wires To Connectors

    3M Dynapro ET 3170 Terminal User’s Installation Guide 5. Using a 1/8-inch flathead screwdriver, turn the terminal block’s screw clockwise until the neutral cable wire is firmly attached to the terminal. - N/L2 NEUTRAL GROUND - L/L1 LINE Figure 4: Connecting AC power cable wires to connectors 6.
  • Page 53: Chapter 4 Mounting

    If the terminal will be placed in an environment where it will be exposed to contaminants, select a mounting method that ensures a NEMA 4X/IP66 seal. If space limitations prevent you from using a rack, panel, or wall mounting option, the post/boom mounting method may be useful. 3M Touch Systems Proprietary Information...
  • Page 54: Figure 6: Security Screw Locations

    3M Dynapro ET 3170 Terminal User’s Installation Guide WARNING To reduce the risks associated with electrical shock or fire which, if not avoided, could result in death or serious injury and/or property damage: Engineer the installation of the ET unit to take into account the operating environment (e.g., thermal, shock/vibration factors).
  • Page 55: Standard Mounting Methods

    The terminal has four screw sockets along the top and bottom lip of the frame and three on each side (Figure 7). These are accessible only from the back of the terminal. Figure 7: Screw hole locations 3M Touch Systems Proprietary Information...
  • Page 56: Figure 8: Side View: Panel Cutout Mount (Without Seal)

    3M Dynapro ET 3170 Terminal User’s Installation Guide Steps To mount the terminal in a panel or wall cutout: 1. Use the full-scale cutout template that came with your unit to mark the dimensions and screw holes on the panel or wall (for cutout dimensions, see Appendix A).
  • Page 57: Optional Mounting Methods

    Pollution Degree 2 environments. Figure 9: Side view: NEMA panel gasket mount Optional mounting methods There are four optional mounting kits available from 3M Touch Systems that allow the terminal to be installed with: NEMA 4X hatch (or NEMA 4X extended hatch)
  • Page 58: Figure 10: Nema 4X Hatch And Extended Hatch

    If you need a seal over both the communication and power connections of the terminal, a NEMA 4X Hatch Kit is available from 3M Touch Systems. This kit comes with a standard NEMA 4X hatch and also with an extended hatch that allows more room for bulky connectors or fittings.
  • Page 59: Figure 12: Desktop Stand

    Mounting Desktop stand An optional stand is available from 3M Touch Systems for mounting the terminal on a desktop, bench, or table. Figure 12: Desktop stand Boom (or post) mount The Boom Mount Kit consists of a special hatch and coupling for mounting the terminal to a boom or post.
  • Page 60: Figure 14: Boom (Or Post) Mount Hatch And Gasket

    3M Dynapro ET 3170 Terminal User’s Installation Guide Figure 14: Boom (or post) mount hatch and gasket The boom mount hatch comes with a precut opening that matches the coupling supplied with the kit. The hatch supplied in the boom mount kit is fastened with the coupling to the post, boom or suspension arm.
  • Page 61: Chapter 5 Configuring

    Others, such as Baud Rate and Parity Sense, determine how the terminal communicates with the host computer. Before operating the terminal, you may need to configure some of the parameters so that the host computer can communicate with it. 3M Touch Systems Proprietary Information...
  • Page 62: Figure 15: Location Of Setup Switch

    3M Dynapro ET 3170 Terminal User’s Installation Guide Calling up and exiting the Setup Screen Use either the Setup switch or an optional keyboard to call up the Setup screen. The Setup switch is a defined touch space as shown in Figure 15.
  • Page 63: Table E: Touch Key Functions: Direct Action Area

    Executes a Recall Setup command. RECALL (Shift/R) The Recall Setup command overwrites all the parameter values programmed in the current Setup session with the values previously saved in nonvolatile Setup memory with a Save Setup command. 3M Touch Systems Proprietary Information...
  • Page 64 3M Dynapro ET 3170 Terminal User’s Installation Guide Table E: Touch key functions: Direct Action Area Touch key Function (keyboard equivalent) The Communication Monitor is for use by programmers or COMMUNICATION service personnel only. MONITOR (Shift/C) Calls up the Communication Monitor that is used to troubleshoot communications between the host and the terminal.
  • Page 65: Changing And Saving Setup Parameters

    Setup screen. On soft reset, the terminal recalls the Setup parameter values saved in the last Setup screen session. Important See “How to test the touch control screen” in this chapter for information about Setup parameter values. 3M Touch Systems Proprietary Information...
  • Page 66: Parameters

    3M Dynapro ET 3170 Terminal User’s Installation Guide Parameters Defaults The first time that power is applied to the terminal, each Setup parameter is set to its original, factory-programmed default value (see Table F). Table F: Default values of Setup parameters...
  • Page 67 (Note: The parameter does not appear as a value, but as the type of cursor you choose.). Reverse-video block Slow blinking (Default) Fast blinking Steady Underline character Slow blinking Fast blinking Steady Invisible 3M Touch Systems Proprietary Information...
  • Page 68: Table G: National Replacement Code Characters

    3M Dynapro ET 3170 Terminal User’s Installation Guide NRC (Remote Programmable), the National Replacement Code parameter, enables you or the host to select a substitute set of international characters for screen display. The NRC parameter options are: Off (Default) Danish...
  • Page 69 è e grave ö o umlaut ü u umlaut German § section sign Ä A umlaut Ö O umlaut Ü U umlaut ß German small sharp ä a umlaut ö o umlaut ü u umlaut 3M Touch Systems Proprietary Information...
  • Page 70 3M Dynapro ET 3170 Terminal User’s Installation Guide Table G: National Replacement Code Characters Nationality Character Character Description of Received Displayed Displayed Character Italian £ pound symbol § section sign ° degree sign ì i grave à a grave ç...
  • Page 71 If a code fails the parity test, the terminal prints the parity error character (PE) on the screen and logs an error message in the Operational Status Window. Ignore 3M Touch Systems Proprietary Information...
  • Page 72: Table H: Touch Control Screen Parity Settings

    3M Dynapro ET 3170 Terminal User’s Installation Guide Parity Sense The terminal uses either odd (default) or even parity checking: Odd (Default): The parity bit and the data bits together contain an odd number of binary 1s. For example, for the data bits 1010100, the parity bit is 0, making the total number of 1s odd (in this example there are a total of three 1s).
  • Page 73 Save Setup and Recall Setup commands. See“After the Setup parameters are saved, they remain selected even after power is turned off. The next time power is turned on, the terminal will be programmed with the previously saved parameter values.”in this chapter for details. 3M Touch Systems Proprietary Information...
  • Page 74: Table I: Effects Of New Line Parameter On Characters Sent To Host

    3M Dynapro ET 3170 Terminal User’s Installation Guide New Line (remote programmable) permits the following settings: Off (Default) On: The New Line parameter selects the control code or codes that the terminal transmits when you press the Return key and, if the auxiliary keypad is in the numeric mode, when you press the Enter key.
  • Page 75: How To Test The Touch Control Screen

    Setup screen is exited. If the input buffer begins to get full, the ET 3170 terminal automatically stalls transmission from the host to prevent buffer overflow. 3M Touch Systems Proprietary Information...
  • Page 76: Table K: Tests Available From The Test Screen Pages

    3M Dynapro ET 3170 Terminal User’s Installation Guide Table K: Tests available from the Test screen pages Tests For details, see page First page Touch Panel Integrity Test Display Geometry Test Standard Character Set Test Extended Character Set Test Keyboard Test...
  • Page 77: Figure 18: Test Screen: Second Page

    2. Press each touch key and make sure it changes to reverse video indicating that the touch cell works properly. If the touch key is touched again, it reverts to normal video. 3M Touch Systems Proprietary Information...
  • Page 78: Figure 19: Touch Panel Integrity Test Screen

    3M Dynapro ET 3170 Terminal User’s Installation Guide Figure 19: Touch Panel Integrity Test screen 3. Press the touch key positions along one row and one column in the touch cell matrix to quickly check the touch panel for opens, shorts, or decoding errors.
  • Page 79: Standard Character Set Test

    Shift/6 on the keyboard. This calls up a picture of the keyboard (without the setup key) on the display. The outline of each key is initially lit in normal video (Figure 20). 3M Touch Systems Proprietary Information...
  • Page 80: Figure 20: Keyboard Test Screen (Example)

    3M Dynapro ET 3170 Terminal User’s Installation Guide Figure 20: Keyboard Test screen (example) To verify correct operation of the keys, touch each key on the keyboard except the setup key. (The setup key is tested when it is pressed to exit the Keyboard Test.) When a key is pressed, the corresponding key on the display toggles from normal to reverse video.
  • Page 81: Figure 21: Stored Screens Test Screen

    256 is displayed here. As screens are stored, this number decreases. % Full: This indicates the percentage of total user-accessible memory occupied by the screens currently stored. If the terminal contains no stored screens, 0 (zero) is displayed here. 3M Touch Systems Proprietary Information...
  • Page 82: Re-Initialize Expansion Memory

    3M Dynapro ET 3170 Terminal User’s Installation Guide The left side of the Stored Screens Directory contains a touch key for each stored screen, identified by screen number. If there are more than 96 stored screens, the directory has multiple pages. In that case, the lower right portion of each directory page has a NEXT PAGE or PREVIOUS PAGE touch key.
  • Page 83: Figure 22: Static Ascii Character Font Test Screen

    Shift/2 on the optional keyboard. Each character in the Static Special Character Font is displayed in double size, including characters that underlie control codes. The characters on the screen are arranged in a checkerboard pattern for easy recognition (Figure 23). 3M Touch Systems Proprietary Information...
  • Page 84: Figure 23: Static Special Character Font Test Screen

    3M Dynapro ET 3170 Terminal User’s Installation Guide Figure 23: Static Special Character Font Test screen The test remains active until you press the keyboard Setup key or touch the Setup switch. This returns the terminal to the Test screen.
  • Page 85: Chapter 6 Maintaining

    Cleaning the touch screen Front surface of touch screen Although the front surface of the touch screen will function even if it is pitted or damaged by a chemical, use a cleaner that does not corrode glass. 3M Touch Systems Proprietary Information...
  • Page 86: Replacing Backlights

    To reduce the risks associated with electrical shock or fire which, if not avoided, could result in death or serious injury and/or property damage: When replacing a fuse of other part, use a part of the type and rating specified by 3M Touch Systems.
  • Page 87: Checking Gaskets

    Make sure there is no debris on gaskets that will prevent a seal. If debris needs to be cleaned from gaskets, do so gently, taking care not to damage the gasket. If gaskets are torn or damaged, return to 3M Touch Systems for servicing. 3M Touch Systems Proprietary Information...
  • Page 89: Chapter 7 Troubleshooting

    Chapter 3). Check the fuse. For instructions on replacing the fuse, see “Replacing the fuse” on page 50. Contact 3M Touch Systems technical support. See “3M Touch Systems support services” on page 3. 3M Touch Systems Proprietary Information...
  • Page 90 Verify that your communication settings (baud rate, parity) are correct. Make sure that you have set the communications port for RS-232 or RS-422/485 communications in the configuration utility. See “3M Touch Systems support services” on page 3. 3M Touch Systems Proprietary Information...
  • Page 91: Appendix A Specifications And Certifications

    APPENDIX A Specifications and certifications Enclosure components The enclosure of the 3M Dynapro ET 3170 terminal consists of the following main components: Bezel/touch screen/display assembly Core electronics assembly Main enclosure Rear access hatch (optional) Figure 24 shows the components of the ET 3170 terminal. The core electronics assembly is part of the bezel assembly.
  • Page 92: Figure 25: Enclosure Dimensions

    3M Dynapro ET 3170 Terminal User’s Installation Guide Enclosure dimensions Imperial Metric Active touch area (wide 10.5" x 9.2" 267 mm x 234 mm x high) Overall size (wide x high 14.0" x 12.55" x 5.48" 356 mm x 319 mm x 139 mm...
  • Page 93: Chemical Resistance

    (NFI) touch screen is made of glass and will withstand most chemicals and their concentrations that do not corrode glass. If the touch screen’s front surface is pitted or damaged by a chemical, the screen continues to function. 3M Touch Systems Proprietary Information...
  • Page 94: Display Specifications

    3M Dynapro ET 3170 Terminal User’s Installation Guide Display specifications Size 10.4 inches (264.16 mm) Type TFT active matrix color LCD Panel colors Contrast ratio (minimum) 150:1 Touch resolution VGA 640 x 480 Viewing angle Horizontal: -70 to +70 degrees Vertical: -70°...
  • Page 95: Operating Conditions

    The following documents ship with the terminal: ET 3170 Terminal User’s Installation Guide and Service Guide Installing the NEMA 4X panel gasket These documents accompany optional kits available from 3M Touch Systems: Installing the NEMA 4X hatch Installing the desktop stand...
  • Page 96: Fcc Compliance

    3M Dynapro ET 3170 Terminal User’s Installation Guide Dust and moisture resistance NEMA 250 Electrical Enclosures, Type 12, Type 4, Type 4X IEC 529 Degrees of Protection Provided by Enclosures, IP66 FCC compliance This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 97 FCC CFR 47, Part 15, Subpart B, Class A Product certifications UL Information Technology Equipment — United States C-UL Information Technology Equipment — Canada CE Information Technology Equipment — Europe C-Tick — Australia, New Zealand 3M Touch Systems Proprietary Information...
  • Page 99: Appendix B Request Identification Command

    If <Pm> is n, that number of bytes is installed <Pd> is the Expansion Memory device type. If <Pd> is 0, NVRAM <Pw> is the write protection status of Expansion Memory. If <Pw> is 0, write protection is disabled (can write) 3M Touch Systems Proprietary Information...
  • Page 100 3M Dynapro ET 3170 Terminal User’s Installation Guide <Po> is a reserved parameter. Example An example of a TCS identification sequence sent to the host in response to this command is: <ESC>[2;10;98304;0;0;0c The TCS type is Model 1030 (2), with firmware version 1.0(10) containing 96K bytes (98304) of Expansion Memory.
  • Page 101: Appendix C Terms And Acronyms

    The front surface of the terminal, comprising the Display Area and the TouchSurround. TouchSurround The area on the front of the terminal, not including the Display Area. This area is touch-sensitive and can be used to access a “hidden” Setup switch. 3M Touch Systems Proprietary Information...
  • Page 102: Abbreviations And Acronyms

    3M Dynapro ET 3170 Terminal User’s Installation Guide Abbreviations and Acronyms The following abbreviations and acronyms are used in this manual. ASCII American Standard Code for Information Interchange BIOS Basic Input Output System Central Processing Unit DRAM Dynamic Random Access Memory...
  • Page 104 Electromagnetic compatibility Power supply immunity standards Electromagnetic emission standards Electrostatic discharge (ESD) Rack mounting and electromagnetic susceptibility Raw Keyboard Test standards Request Identification Command Enclosure cleaning RS-232 communication components of RS-422 communication Error messages RS-485 communication 3M Touch Systems Proprietary Information...
  • Page 105 3M Dynapro ET 3170 Terminal User’s Installation Guide electromagnetic emission FCC compliance Safety safety notices Static ASCII Character Font Test standards Static Special Character Font Security screws Test Serial communication Status messages Setup Parameters Stop Bits parameter changing Stored Screens Test...
  • Page 108 ET 3170 Terminal (Series B) Service Guide Read and understand all safety information before installing and using this product. 3M Touch Systems Proprietary Information...
  • Page 109 3M Touch Systems, a subsidiary of 3M, is prohibited. Notice Given the variety of factors that can affect the use and performance of a 3M Touch Systems Product (the “Product”), including that solid state equipment has operation characteristics different from electromechanical equipment, some of which factors are uniquely within User’s knowledge and control, it is essential...
  • Page 110 Intended use The 3M Dynapro ET 3170 terminal is intended to provide touch screen functions for industrial applications when the terminal is connected to a host computer. The ET 3170 terminal is not intended for use in hazardous locations. Using the terminal in conditions exceeding these ratings will invalidate the warranty and will be solely the user’s risk and responsibility.
  • Page 111 Do not use an ET unit that is not rated to NEMA 4X/IP66 in an environment that requires a NEMA 4X/IP66 seal. When replacing a fuse of other part, use a part of the type and rating specified by 3M Touch Systems.
  • Page 112 Important Safety Information Safety labels The following safety symbols appear on your 3M Dynapro industrial product and its packaging materials: Symbol Meaning Consult user instructions. Caution: Risk of electric shock. Caution: Item is susceptible to electrostatic discharge (ESD) damage if proper precautions are not taken.
  • Page 114 What it’s about ..................1 Chapter 2 Setting jumpers............... 3 Tools required ..................3 Setting jumpers on the logic board............3 Setting jumpers on the I/O filter board..........6 Connector pin-outs and cable diagrams ..........8 3M Touch Systems Proprietary Information...
  • Page 116: What It's About

    About the Service Guide Who should read this Service Guide The ET 3170 Terminal Service Guide is for qualified service personnel who need to make adjustments inside the enclosure of the 3M Dynapro ET 3170 terminal. WARNING To reduce the risks associated with electrical shock or fire which, if not avoided, could result in death or serious injury and/or property damage: Follow all product and accessory installation instructions.
  • Page 118: Chapter 2 Setting Jumpers

    To ensure compliance with electrical codes and safe operation of the ET unit, have a licensed journeyman electrician familiar with local codes perform all wiring tasks. 3M Touch Systems Proprietary Information...
  • Page 119 3M Dynapro ET 3170 Terminal Service Guide To set the jumpers on the logic board: 1. Put on a grounding strap. Important To prevent damage from electrostatic discharge, be sure you are wearing a grounding wrist or ankle strap before touching any components inside the enclosure.
  • Page 120 Make sure that the setup screen is correctly set for your communication needs. If you are using RS-422 or RS-485, set and save the Address parameter at RS-422. There is not a separate Address parameter for RS-485. 3M Touch Systems Proprietary Information...
  • Page 121: Setting Jumpers On The I/O Filter Board

    3M Dynapro ET 3170 Terminal Service Guide Setting jumpers on the I/O filter board This procedure is necessary only if you wish to add jumpers on the I/O filter board. These jumpers add 100 ohm termination resistors across the TX+, TX- or RX+, RX- signal lines.
  • Page 122 RX+ and RX- pins. 8. Close the unit by releasing the locking arm and then locking the unit with the Allen key. 9. If your unit had security screws, replace them now. 10. Reconnect power to the unit. 3M Touch Systems Proprietary Information...
  • Page 123: Connector Pin-Outs And Cable Diagrams

    3M Dynapro ET 3170 Terminal Service Guide Connector pin-outs and cable diagrams The following illustrations show the suggested connector pin-outs and cable diagrams for RS-422 and RS-485 communications. Your host system may have a different pin-out than presented in the drawing.
  • Page 124 Table B: COM A RS-422 connector pin-out (full duplex) Signal Description In/Out Shield Ground Balanced Transmit data + Balanced Transmit data - Balanced Receive data + Balanced Receive data - Connect only one end of the cable to shield ground. 3M Touch Systems Proprietary Information...
  • Page 125 3M Dynapro ET 3170 Terminal Service Guide RS-485 communication To make a cable for RS-485 communications, use the pin-out shown in Table C. For maximum cable length, refer to the EIA RS-485 Specification Standard. Table C: COM A RS-485 connector pin-out (half duplex)